CT measurement of prostate volume using OsiriX® viewer is reliable, repeatable, and not dependent on observer, CT protocol, or contrast enhancement in dogs.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Salonen Hanna M, Åhlberg Tuuli M, Laitinen-Vapaavuori Outi M, Mölsä Sari H

Аннотация

Computed tomography (CT) is an established method for evaluating dogs with suspected prostatic disease; however, publications assessing the effects of varying factors on prostate volume measurements are lacking. The objectives of this two-part, observer agreement, methods comparison study were to assess observer agreement and the effects of varying CT technical parameters for volume measurements of canine prostate glands on CT images using OsiriX® DICOM viewer software. In the first retrospective study, two observers measured prostate volumes of 13 client-owned dogs thrice on noncontrast and contrast CT images. In the second prospective study, two observers measured the prostate volume of 10 cadavers using five different CT protocols and eight cadavers using three slice thicknesses. Observer agreement analyses were performed, and prostatic CT volume measurements were compared with water displacement volume measurements. Intra- and interobserver variability and the effect of contrast enhancement were found to be minimal when a one-way analysis of variance model and intraclass correlation coefficients were used. No significant differences emerged between different protocols and slice thicknesses using a linear mixed effects model. When the prostate CT volume was compared using a Bland-Altman plot with the reference volume acquired by the water displacement method, agreement without consistent bias between the methods was shown, and over 90% of measurements were located within the 95% limits of agreement. The findings supported using OsiriX® software for CT prostatic volume measurements in dogs.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты