DOI 10.1161/circep.124.012794

Медицинская библиотека · Circulation. Arrhythmia and electrophysiology · 2024

Pulsed Field Ablation Using Focal Contact Force-Sensing Catheters for Treatment of Atrial Fibrillation: 1-Year Outcomes of the ECLIPSE AF Study.

Anić Ante, Phlips Thomas, Brešković Toni, Mediratta Vikramaditya, Girouard Steven, Jurišić Zrinka, Sikirić Ivan, Lisica Lucija, Koopman Pieter, Antole Nathalie, Vijgen Johan

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

Pulsed field ablation (PFA) is a promising treatment for atrial fibrillation. We report 1-year freedom from atrial arrhythmia outcomes using monopolar PFA delivered through 3 commercial, contact force-sensing focal catheters.

METHODS

ECLIPSE AF (Safety & Clinical Performance Study of Catheter Ablation With the Centauri System for Patients With Atrial Fibrillation; NCT04523545) was a prospective, single-arm, multicenter study evaluating acute and chronic safety and performance using the CENTAURI system to deliver focal PFA with TactiCath SE, StablePoint, and ThermoCool ST. Patients with paroxysmal or persistent atrial fibrillation underwent pulmonary vein (PV) isolation under deep sedation or general anesthesia and returned for remapping at 90 days to evaluate chronic durability. Freedom from atrial arrhythmia was evaluated continuously through 12 months using standard rhythm monitoring for symptomatic episodes and 24-hour Holter at 6 and 12 months.

RESULTS

Eighty-two patients (74% male, 51.2% paroxysmal, and 58.5% deep sedation) were treated. PV isolation was achieved in 100% of targeted veins (322/322) with first-pass isolation in 92.2% (297/322). There were 4 primary safety events in 4 patients (4.9%, 4/82); 1 nonembolic stroke due to exacerbated cardiac tamponade secondary to catheter perforation and 3 hemorrhagic vascular access complications. There were no incidences of adverse event fistula, diaphragmatic paralysis, myocardial infarction, pericarditis, thromboembolism, PV stenosis, transient ischemic attack, or death. Eighty patients (98%) underwent remapping. Optimized PFA cohorts 3, 4, and 5 showed per-patient isolation rates of 60%, 73%, and 81% and per-PV isolation rates of 84%, 90%, and 92%, respectively. One-year freedom from atrial arrhythmia was 80.2% (95% CI, 69.7%-87.4%) for the entire patient sample, including 41 patients who underwent repeat focal PFA with the CENTAURI system at remapping.

CONCLUSIONS

This study demonstrated that optimization of focal PFA with 3 contact force-sensing, solid-tip ablation catheters resulted in the progressive improvement of PV isolation durability at 3-month remapping and high freedom from atrial arrhythmia survival rates, providing a promising focal PFA treatment option integrated with current ablation workflows.

Для цитирования: Anić Ante, Phlips Thomas, Brešković Toni, Mediratta Vikramaditya, Girouard Steven, Jurišić Zrinka, Sikirić Ivan, Lisica Lucija, Koopman Pieter, Antole Nathalie, Vijgen Johan. Pulsed Field Ablation Using Focal Contact Force-Sensing Catheters for Treatment of Atrial Fibrillation: 1-Year Outcomes of the ECLIPSE AF Study.. Circulation. Arrhythmia and electrophysiology. 2024. DOI: 10.1161/circep.124.012794.