MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.avsg.2018.02.020

Медицинская библиотека · Annals of vascular surgery · 2018

Nine-Month Outcomes of the DURABILITY Iliac Study on Self-Expanding Stents for Symptomatic Peripheral Artery Disease.

Faries Peter, Jaff Michael, Peeters Patrick, Khatib Yazan, Roberts David, Bosiers Marc, Malik Rajesh, Ravin Reid, Rundback John

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

The DURABILITY Iliac clinical study evaluated the safety and effectiveness of 2 nitinol self-expanding stents for the treatment of atherosclerotic common and external iliac artery lesions up to 10 cm in length and >50% stenosis in subjects with Rutherford classification peripheral arterial disease stages 2-4.

METHODS

DURABILITY Iliac was a prospective, multicenter, core lab adjudicated, nonrandomized clinical study enrolling 75 subjects from 15 sites in the United States and Europe. Clinical follow-up visits were at 30 days, 9 months, and 1, 2, and 3 years after procedure. The primary outcome measured was the major adverse event (MAE) rate at 9 months, defined as a composite of periprocedural death, in-hospital myocardial infarction (MI), clinically driven target lesion revascularization (CD-TLR), and amputation of the treated limb through 9 months after procedure. Secondary outcomes included primary patency rate at 9 months, clinically driven target vessel revascularization (CD-TVR), change in ankle-brachial index, and change in Walking Impairment Questionnaire score at 30 days and 9 months. Device success was defined as the ability to deploy the stent as intended at the treatment site.

RESULTS

The MAE rate at 9 months was 1.3% (1/75), with 1 subject experiencing a CD-TLR. No periprocedural deaths, MIs, or amputations were reported. Primacy patency at 9 months was 95.8%. Freedom from CD-TVR was 98.6% at 9 months. Subjects improved in Walking Impairment Questionnaire scores for all categories (walking impairment, walking speed, walking distance, and stair climbing) at the 30-day and 9-month visit. Device success was 100%.

CONCLUSIONS

The 9-month results of the DURABILITY Iliac study demonstrate the safety and effectiveness of 2 nitinol self-expanding stents for the treatment of atherosclerotic lesions of the common and external iliac arteries.

Для цитирования: Faries Peter, Jaff Michael, Peeters Patrick, Khatib Yazan, Roberts David, Bosiers Marc, Malik Rajesh, Ravin Reid, Rundback John. Nine-Month Outcomes of the DURABILITY Iliac Study on Self-Expanding Stents for Symptomatic Peripheral Artery Disease.. Annals of vascular surgery. 2018. DOI: 10.1016/j.avsg.2018.02.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.