MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijcard.2017.10.069

Медицинская библиотека · International journal of cardiology · 2018

Reactive hyperemia-peripheral arterial tonometry is useful for assessment of not only endothelial function but also stenosis of the digital artery.

Kishimoto Shinji, Matsumoto Takeshi, Maruhashi Tatsuya, Iwamoto Yumiko, Kajikawa Masato, Oda Nozomu, Matsui Shogo, Hashimoto Haruki, Hidaka Takayuki, Kihara Yasuki, Chayama Kazuaki, Goto Chikara, Aibara Yoshiki, Yusoff Farina Binti Mohamad, Nakashima Ayumu, Noma Kensuke, Higashi Yukihito

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Although reactive hyperemia-peripheral arterial tonometry (RH-PAT) is widely used for assessment of endothelial function, RH index (RHI) cannot be measured in some cases when pulse wave amplitude (PWA) is very low. Decrease in PWA is mainly caused by proper palmar digital artery (PPDA) stenosis. The purpose of this study was to evaluate the relationship between PWA measured by RH-PAT and stenosis of the PPDA measured by digital subtraction angiography and to evaluate the limitation of assessment of endothelial function measured by RHI in patients with PPDA stenosis.

METHODS

We measured baseline PWA in 51 fingers including the first to third fingers of both hands in 10 patients who had PPDA stenosis and in 66 fingers that were the first fingers of both hands in 33 subjects who had no PPDA stenosis. Severe stenosis was defined as over 75% by lower percent diameter stenosis between two PPDAs in a finger.

RESULTS

PWA was significantly correlated with stenosis of the digital artery (r=-0.55; P<0.0001). A PWV value of 300mV was the optimal cut-off value for severe stenosis (sensitivity, 84.0%; specificity, 88.5%). Log RHI was significantly lower in patients with PPDA stenosis than in subjects without PPDA stenosis (0.33±0.27 versus 0.73±0.27, P=0.007).

CONCLUSIONS

RH-PAT may be useful for assessment of not only endothelial function but also PPDA stenosis. RHI may be underestimated in patients with PPDA stenosis. We should pay attention to low baseline PWA when measuring RHI.

CLINICAL TRIAL REGISTRATION INFORMATION: URL for clinical trial: http://UMIN; registration number for clinical trial: UMIN000003409.

Для цитирования: Kishimoto Shinji, Matsumoto Takeshi, Maruhashi Tatsuya, Iwamoto Yumiko, Kajikawa Masato, Oda Nozomu, Matsui Shogo, Hashimoto Haruki, Hidaka Takayuki, Kihara Yasuki, Chayama Kazuaki, Goto Chikara, Aibara Yoshiki, Yusoff Farina Binti Mohamad, Nakashima Ayumu, Noma Kensuke, Higashi Yukihito. Reactive hyperemia-peripheral arterial tonometry is useful for assessment of not only endothelial function but also stenosis of the digital artery.. International journal of cardiology. 2018. DOI: 10.1016/j.ijcard.2017.10.069.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.