MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mnm.0000000000000188

Медицинская библиотека · Nuclear medicine communications · 2014

Radioguided occult lesion localization for minimally invasive parathyroidectomy: technical consideration and feasibility.

Ilgan Seyfettin, Ozbas Serdar, Bilezikci Banu, Sengezer Tugba, Aydin Oguz Ugur, Gursoy Alptekin, Kocak Savas

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE OF THE REPORT: Minimally invasive parathyroidectomy (MIP) constitutes one of the main surgical approaches for the patient with primary hyperparathyroidism (PHPT) caused by a single parathyroid adenoma. The purpose of the study was to investigate the feasibility of radioguided occult lesion localization (ROLL) for MIP and the potential effects of the method in histopathologic evaluation.

MATERIALS AND

METHODS

Twenty-two patients, diagnosed with PHPT biochemically and candidates for surgery, underwent ROLL-guided MIP (ROLL-MIP). Parathyroid adenomas were searched for and identified with the guidance of an intraoperative gamma probe. The final diagnosis was confirmed by histopathologic analysis. All specimens were analyzed for the presence of parenchymal hemorrhage, congestion, neutrophil leukocyte infiltration, necrosis, cystic degeneration, subcapsular hematoma, subcapsular fibrin/neutrophil leukocyte infiltration, and disarray of the fibrous capsule of adenoma.

RESULTS

All injected lesions were effectively located over the skin with very high count rates depending on the injected activity and location of the lesion. Serum calcium and parathyroid hormone (PTH) levels normalized in all patients and stayed within the normal range during the follow-up period. None of the patients who underwent ROLL-MIP suffered temporary or permanent recurrent laryngeal nerve injuries. The mean operative time was 23 ± 7 min. Parenchymal hemorrhage, congestion, subcapsular hematoma, and fibrin/neutrophil leukocyte infiltration were common histopathologic features.

CONCLUSION

The use of ROLL-MIP in patients with PHPT due to a single parathyroid adenoma in the neck is technically safe and effective. It is more valuable in scintigraphy-negative patients when parathyroid adenoma is either demonstrated on ultrasonography by typical findings or confirmed by PTH washout. The ROLL-MIP technique does not impair the postoperative histopathologic examination of the parathyroid glands.

Для цитирования: Ilgan Seyfettin, Ozbas Serdar, Bilezikci Banu, Sengezer Tugba, Aydin Oguz Ugur, Gursoy Alptekin, Kocak Savas. Radioguided occult lesion localization for minimally invasive parathyroidectomy: technical consideration and feasibility.. Nuclear medicine communications. 2014. DOI: 10.1097/mnm.0000000000000188.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.