Melanoma detection in Italian pigmented lesion clinics.

Argenziano G, Moscarella E, Annetta A, Battarra V C, Brunetti B, Buligan C, Cantisani C, Capizzi R, Carbone A, Carlino A, Corsetti V, Damiano A, De Salvo V, De Simone P, Di Caterino P, Fargnoli M C, Ferrari A, Fossati B, Frascione P, Ghigliotti G, González Inchaurraga M A, Guerriero C, Landi C, Mazzoni L, Mirizzi S, Palazzo G, Pedretti A, Peris K, Piemonte P, Rossi A, Satta R, Savoia F, Scalvenzi M, Stanganelli I, Stinco G, Zampieri P, Zalaudek I

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

AIM: Accuracy in melanoma detection is important to recognize early curable melanomas and to minimize the unnecessary excision of benign lesions. The aim of this paper was to evaluate melanoma screening accuracy of Italian pigmented lesion clinics in terms of number needed to excise (NNE), melanoma thickness, and number of melanomas diagnosed during patient follow-up.

METHODS

Information on all skin tumors excised in 2011 were extracted from the databases of the participating centers. Information whether the lesion was excised at the baseline examination or during patient follow-up was recorded, as well as the overall number of patients examined in each center in 2011.

RESULTS

After e-mail solicitation, 22 of 40 centers agreed to participate. A total of 8229 excised lesions were collected. The overall number of examined patients was 86.564, thus 9.5% of screened patients had a lesion removed. Of the excised lesions, 866 were diagnosed as melanoma (1% of examined patients) and 5311 (88.9%) were melanocytic nevi. Three NNE were calculated giving values of 7.9 excised lesions to find 1 melanoma, 7.1 melanocytic lesions to find 1 melanoma, and 3.7 lesions to find 1 skin malignancy. The median melanoma thickness was 0.6 mm, with only 15.1% of melanomas ≥ 1 mm of thickness. Melanomas detected over time were 96 (11.1%; mean thickness, 0.3 mm), with 15.6% of lesions excised after short-term follow-up and 84.4% after long-term follow-up.

CONCLUSION

The NNE values comparable to those achieved in specialized clinical settings and the high number of early melanomas diagnosed at the baseline examination or during patient follow-up indicate a high level of accuracy in melanoma screening achieved by Italian pigmented lesion clinics.

Для цитирования: Argenziano G, Moscarella E, Annetta A, Battarra V C, Brunetti B, Buligan C, Cantisani C, Capizzi R, Carbone A, Carlino A, Corsetti V, Damiano A, De Salvo V, De Simone P, Di Caterino P, Fargnoli M C, Ferrari A, Fossati B, Frascione P, Ghigliotti G, González Inchaurraga M A, Guerriero C, Landi C, Mazzoni L, Mirizzi S, Palazzo G, Pedretti A, Peris K, Piemonte P, Rossi A, Satta R, Savoia F, Scalvenzi M, Stanganelli I, Stinco G, Zampieri P, Zalaudek I. Melanoma detection in Italian pigmented lesion clinics.. Giornale italiano di dermatologia e venereologia : organo ufficiale, Societa italiana di dermatologia e sifilografia. 2014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.