m+Medelevator.RU
← Поиск публикаций
Journal of cataract and refractive surgery · 2024

Ten-year follow-up of posterior chamber phakic intraocular lens with central port design in patients with low and normal vault.

СтатьяСравнительное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Alfonso-Bartolozzi Belén, Fernández-Vega-Cueto Luis, Lisa Carlos, Palacios Ana, Madrid-Costa David, Alfonso José F

Аннотация

PURPOSE: To assess the clinical outcomes and postoperative complications of the implantable collamer lens (ICL) with a central port throughout 10 years of follow-up in patients with low and normal vault.

SETTING: Fernández-Vega Ophthalmological Institute, Oviedo, Spain.

DESIGN: Retrospective and comparative case series.

METHODS: This study included eyes that underwent a V4c ICL implantation with 10 years of follow-up. The eyes were divided into 2 groups according to the vault at 1 year postoperatively: vault <250 μm and between 250 μm and 800 μm. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), intraocular pressure (IOP), endothelial cell density (ECD), vault, complications, and secondary surgeries were analyzed.

RESULTS: 37 and 90 eyes were enrolled in the low and normal-vault groups, respectively. No differences in UDVA, CDVA, and refraction were found between the groups over 10 years of follow-up. No cases developed ICL-induced anterior subcapsular opacity over the follow-up period. 2 (5.4%) and 8 (8.9%) eyes in the low and normal-vault groups, respectively, required ICL exchange. 1 (2.8%) and 2 (2.2%) eyes in the low and normal-vault groups, respectively, required excimer laser to correct residual refractive error. The IOP remained stable throughout the 10-year follow-up. The loss in ECD from that preoperatively to 10 years postoperatively was 3.8% and 4.5% in the low and normal-vault groups, respectively ( P = .4). No pigment dispersion glaucoma or other vision-threatening complications were reported.

CONCLUSIONS: This study shows good long-term outcomes of the V4c ICL, supporting that the central hole provides safety to the procedure and prevents the potential risk associated with low vault.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты