m+Medelevator.RU
← Поиск публикаций
Surgery today · 2011

Peroral placement of a self-expandable covered metallic stent using an overtube for malignant gastroduodenal obstructions.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ikeda Tetsuo, Ueda Naoyuki, Yonemura Yusuke, Mashino Kohjiro, Kabashima Akira, Watanabe Kiminori, Fujii Kyuzo, Tashiro Hideya, Sakata Hisanobu

Аннотация

PURPOSE: To evaluate the technical feasibility and safety of overtube-guided covered metallic stent placement as palliative treatment for patients with inoperable malignant gastric outlet obstructions.

METHODS: To relieve the symptoms of severe nausea and recurrent vomiting in five patients with inoperable gastric cancer, we used an overtube (Long overtube; Sumitomo Bakelite, Tokyo, Japan) to place large-diameter, self-expandable, covered esophageal Ultraflex stents (inner diameter 22-28 mm, length 10 or 12 cm; Boston Scientific, Watertown, MA, USA). Success was defined both technically and clinically.

RESULTS: The stent placement was technically successful in all patients and resulted in improvement of symptoms in all five patients, four of whom were thereafter able to ingest solid food. The remaining patient, a 94-year-old man, was unable to ingest food because of dysmasesis. During the mean follow-up of 17 weeks, there was no stent reocclusion and no life-threatening complications developed.

CONCLUSIONS: The placement of a large diameter, self-expandable, covered esophageal stent using an overtube appears to be effective for the palliative treatment of malignant gastric outlet obstruction.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты