Performance of brief ICF-sleep disorders and obesity core set in obstructive sleep apnea patients.

Xie Liang, Wu Qinhan, Hu Weiping, Li Wenjing, Xiang Guiling, Hao Shengyu, Guo Chengyao, Jiang Hong, Wu Xiaodan, Wu Xu, Li Shanqun

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Clinical questionnaires are mainly applied as screening tools for identification of the Obstructive sleep apnea (OSA) patients. Little attention has been paid to assess the body functions and health status of the patients. International Classification of Functioning, Disability and Health (ICF) was designed for better understanding and describing functioning and disability of patients. This study adopted the Brief ICF-Sleep Disorders and Obesity Core Set to evaluate the impairment of functioning and health status of OSA patients.

METHODS

Five hundred ninety-two participants were enrolled in this cross-sectional study. Data were collected using Brief ICF-Sleep Disorders and Obesity Core Set Polysomnography was performed and basic characteristics of the patients were recorded.

RESULTS

The scores for the component Body Functions and Code b130, b134, b140, b440, b530, s330, d160, d240, d450 of the two core sets were significantly different among the patients divided by apnea-hypopnea index (AHI) or oxygen saturation (SaO2) nadir, but the frequency of code s330, d160, d240, d450 was low. The Body Functions component of the both sets were closely related to neck circumference (NC), body mass index (BMI), apnea-hypopnea index (AHI) of the OSA patients. Body Functions of the Brief ICF-Sleep Disorders performed better with a threshold of 4 with sensitivity, specificity and area under the receiver operating characteristic curve (AUC) as 0.62, 0.74, 0.68(AHI ≥ 5), 0.69, 0.63, 0.66 (AHI ≥ 15), 0.75, 0.56, 0.66 (AHI ≥ 30), 0.56, 0.70, 0.63 (SaO2 nadir≤90%), 0.67, 0.66, 0.66 (SaO2 nadir<85%), 0.71, 0.59, 0.65 (SaO2 nadir<80%), separately.

CONCLUSION

The Body Functions component of both two sets could be an evaluation tool of impairment of body functions for OSA patients. The Brief ICF-Sleep Disorders Body Functions component performed better with a threshold of 4 and might provide a new insight for physicians to assess OSA patients.

Для цитирования: Xie Liang, Wu Qinhan, Hu Weiping, Li Wenjing, Xiang Guiling, Hao Shengyu, Guo Chengyao, Jiang Hong, Wu Xiaodan, Wu Xu, Li Shanqun. Performance of brief ICF-sleep disorders and obesity core set in obstructive sleep apnea patients.. Respiratory research. 2020. DOI: 10.1186/s12931-020-01404-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.