m+Medelevator.RU
← Поиск публикаций
Cardiovascular intervention and therapeutics · 2024

Assessment of fractal ratio of vessel diameters in coronary bifurcation lesions by angiography and intravascular ultrasound.

СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Murasato Yoshinobu, Kinoshita Yoshihisa, Yamawaki Masahiro, Okamura Takayuki, Nagoshi Ryoji, Fujimura Tatsuhiro, Takeda Yoshihiro, Fujii Kenichi, Yamada Shin-Ichiro, Shinke Toshiro, Shite Junya

Аннотация

Physiological coronary branching at the bifurcation has a constant fractal ratio (FR) of the diameter of the mother vessel to the sum of daughter vessels on quantitative coronary angiography (QCA). We sought to investigate the FR of diseased coronary bifurcations using QCA and intravascular ultrasound (IVUS) and its impact on late lumen loss after percutaneous coronary intervention (PCI). In multicentre prospective studies of the J-REVERSE and 3D OCT Bifurcation Registry, 402 and 109 bifurcations treated with stenting that completed QCAs and IVUS examinations, respectively were analysed. FR was investigated at the reference sites pre-PCI and the minimum lumen diameter (MLD) post-PCI. In the QCA analysis, constant FR was observed in the pre-PCI reference (0.62 ± 0.08) and in the post-PCI MLD site (0.74 ± 0.10), which was greater (p < 0.05). In the IVUS analysis, the constant FR in the post-PCI MLD site (0.67 ± 0.06) was similar to that in the pre-PCI reference (0.66 ± 0.06) and close to the physiological FR value (0.678). The fourth quintile of pre-PCI reference FR in the IVUS analysis showed numerically least late lumen loss in proximal main vessel (MV) (0.16 ± 0.22 mm) and distal MV (0.13 ± 0.32 mm) and significantly less in the side branch compared to higher FR quintile (- 0.14 ± 0.27 mm vs. 0.10 ± 0.19 mm, p = 0.004), while no relationship was found in the QCA analysis. FR in the diseased coronary bifurcation was more accurately assessed on IVUS than on QCA, and the accomplishment of physiological FR might lead to less late lumen loss after bifurcation PCI.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты