MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.amjcard.2022.06.018

Медицинская библиотека · The American journal of cardiology · 2022

Comparison of and Frequency of Mortality, Left Ventricular Assist Device Implantation, Ventricular Arrhythmias, and Heart Transplantation in Patients With Familial Versus Nonfamilial Idiopathic Dilated Cardiomyopathy.

Rao Roopa A, Kozaily Elie, Jawaid Omar, Sabra Mohammad, El-Am Edward A, Chaaya Rody G Bou, Woiewodski Leanne, Elsemesmani Hussein, Ramchandani Juhi, Shah Chirag, Guglin Maya, Das Mithilesh K

СтатьяПеревод пока не подготовлен

Аннотация

We postulated that familial idiopathic dilated cardiomyopathy (F-IDC) is associated with a worse prognosis than nonfamilial IDC (nonF-IDC). Patients with F-IDC had either a strong family history and/or proved genetic mutations. We studied long-term prognosis (mean follow-up: 6.1 ± 4.1 years) of 162 patients with IDC (age: 55.5 ± 17.9 years, men: 57.8%, 50% F-IDC) with an implantable cardioverter-defibrillator or cardiac resynchronization therapy. The primary end point was a composite of death, left ventricular (LV) assist device implant, or heart transplantation. The secondary end point was a ventricular arrhythmia event. There was no significant difference in the prevalence of diabetes, hypertension, New York Heart Association class, medical therapy, and years of follow-up between the F-IDC and nonF-IDC groups. Patients with F-IDC were younger than patients with nonF-IDC (49.1 ± 17.0 years vs 61.6 ± 16.5 years, p <0.001). Mean LV ejection fraction was significantly lower in F-IDC group than in the nonF-IDC group (26 ± 12% vs 31 ± 12%, p = 0.022). The primary end point was achieved in 54 patients in F-IDC group (66.7%) versus 19 in the nonF-IDC group (23.5%) (p <0.001). The Kaplan-Meier survival estimates for the composite end point and for ventricular arrhythmia were significantly lower in the F-IDC versus nonF-IDC (log-rank p ≤0.001 and 0.04, respectively). F-IDC was the only multivariable predictor of the primary composite end point (hazard ratio 3.419 [95% confidence interval 1.845 to 6.334], p <0.001). The likelihood of LV remodeling manifested by LV ejection fraction improvement (≥10%) was significantly lower in F-IDC than nonF-IDC (27.1% vs 44.8%, p = 0.042). In conclusion, F-IDC is a predictor of mortality, need for LV assist device, or heart transplantation. F-IDC is associated with significantly lower event-free survival for primary end point and ventricular arrhythmia than nonF-IDC. F-IDC has significantly lower likelihood of LV reverse remodeling than nonF-IDC.

Для цитирования: Rao Roopa A, Kozaily Elie, Jawaid Omar, Sabra Mohammad, El-Am Edward A, Chaaya Rody G Bou, Woiewodski Leanne, Elsemesmani Hussein, Ramchandani Juhi, Shah Chirag, Guglin Maya, Das Mithilesh K. Comparison of and Frequency of Mortality, Left Ventricular Assist Device Implantation, Ventricular Arrhythmias, and Heart Transplantation in Patients With Familial Versus Nonfamilial Idiopathic Dilated Cardiomyopathy.. The American journal of cardiology. 2022. DOI: 10.1016/j.amjcard.2022.06.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.