Transplantation proceedings · 2022
Orthotopic Heart Transplant with Concurrent Supracoronary Ascending Aortic Replacement.
Клинический случайСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Borys Todurov, Oleh Loskutov, Gavrylo Kovtun, Olena Dyadyk, Dmytro Loskutov, Maksym Goncharenko
Аннотация
BACKGROUND: We report a case of successful orthotopic heart transplant with concurrent supracoronary ascending aortic replacement (SCAAR) using a vascular conduit.
CASE PRESENTATION: An orthotopic heart transplant was performed on a 29-year-old White man with idiopathic dilated cardiomyopathy and reduced ejection fraction (20%). During the revision of the donor heart, a wall defect was detected in the ascending part of the donor aorta that could not be corrected. It was decided to perform a SCAAR using a 22-mm polytetrafluoroethylene vascular conduit and double-patch sandwich technique with Teflon patches. Two months later postoperative computed topography scan demonstrated sufficient patency of the vascular conduit and aorta with an improvement in the general somatic and functional state of the patient, and normal systolic and diastolic function of the transplanted heart.
CONCLUSIONS: Our clinical case is unique in the complexity of the procedure with potential high intraoperative and early postoperative risks as well as the fact that SCAAR was performed immediately after heart transplant. In this clinical case, reconstruction of the ascending aorta with a vascular conduit is a strategically correct solution in the event of aortic defects that cannot be corrected with a suture technique.
CASE PRESENTATION: An orthotopic heart transplant was performed on a 29-year-old White man with idiopathic dilated cardiomyopathy and reduced ejection fraction (20%). During the revision of the donor heart, a wall defect was detected in the ascending part of the donor aorta that could not be corrected. It was decided to perform a SCAAR using a 22-mm polytetrafluoroethylene vascular conduit and double-patch sandwich technique with Teflon patches. Two months later postoperative computed topography scan demonstrated sufficient patency of the vascular conduit and aorta with an improvement in the general somatic and functional state of the patient, and normal systolic and diastolic function of the transplanted heart.
CONCLUSIONS: Our clinical case is unique in the complexity of the procedure with potential high intraoperative and early postoperative risks as well as the fact that SCAAR was performed immediately after heart transplant. In this clinical case, reconstruction of the ascending aorta with a vascular conduit is a strategically correct solution in the event of aortic defects that cannot be corrected with a suture technique.