Five-year outcomes of transcatheter mitral valve replacement in patients with severe symptomatic mitral regurgitation: results from the Tendyne Expanded Clinical Study.

Muller David W M, Duncan Alison, Sorajja Paul, Dahle Gry, Babaliaros Vasilis, Lubos Edith, Badhwar Vinay, Denti Paolo, Eng Marvin H, Grayburn Paul, Bethea Brian, Walters Darren, Nickenig Georg, Petronio Anna Sonia, Donal Erwan, Thourani Vinod H, Mumtaz Mubashir, Modine Thomas, Dumonteil Nicolas, Obadia Jean-Francois, Kapadia Samir R, Guerrero Mayra E, De Medeiros Ricardo, McNutt Robert, Nie Hong, Chuang Michael, Blanke Philipp, Conradi Lenard

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

AIMS: Transcatheter mitral valve replacement (TMVR) with the Tendyne Mitral Valve System is a treatment option for patients with severe symptomatic mitral regurgitation (MR) unsuitable for conventional mitral valve surgery or transcatheter edge-to-edge repair (TEER). This study sought to evaluate the safety and effectiveness of TMVR through 5-year follow-up.

METHODS AND

RESULTS

The Tendyne Expanded Clinical Study is a prospective, single-arm, multicentre study that enrolled patients between November 2014 and June 2020. The study enrolled 191 patients (mean age 74.1 ± 8.0 years, 62.8% male, 70.2% New York Heart Association Class (NYHA) class III/IV, 88.5% secondary MR), of whom 186 (97.4%) underwent TMVR with Tendyne. MR grade decreased from ≥3+ in 99.5% patients at baseline to grade ≤1+ in 95.3% at 5 years. In those patients surviving to 5 years (n = 49), durable symptomatic improvement was evidenced by 73.5% patients being in NYHA class I/II at 5 years. The Kansas City Cardiomyopathy Questionnaire overall summary score increased from 48.5 ± 22.5 points at baseline to 67.6 ± 21.5 points at 5 years. Serious adverse events that occurred through 5 years included life-threatening bleeding (11.5%), fatal bleeding (2.6%), renal insufficiency/failure (28.8%), endocarditis (7.3%), device thrombosis (5.8%), and new onset atrial fibrillation (13.1%). No structural device degeneration or device embolism occurred through 5 years.

CONCLUSIONS

The Tendyne TMVR was effective at achieving immediate and sustainable elimination of MR, which was associated with symptomatic improvement and absence of structural valve degeneration in a high-risk cohort over 5 years. These findings support TMVR with the Tendyne System as an alternative for patients with appropriate mitral valve anatomy and symptomatic secondary MR unsuitable for mitral surgery or TEER.

Для цитирования: Muller David W M, Duncan Alison, Sorajja Paul, Dahle Gry, Babaliaros Vasilis, Lubos Edith, Badhwar Vinay, Denti Paolo, Eng Marvin H, Grayburn Paul, Bethea Brian, Walters Darren, Nickenig Georg, Petronio Anna Sonia, Donal Erwan, Thourani Vinod H, Mumtaz Mubashir, Modine Thomas, Dumonteil Nicolas, Obadia Jean-Francois, Kapadia Samir R, Guerrero Mayra E, De Medeiros Ricardo, McNutt Robert, Nie Hong, Chuang Michael, Blanke Philipp, Conradi Lenard. Five-year outcomes of transcatheter mitral valve replacement in patients with severe symptomatic mitral regurgitation: results from the Tendyne Expanded Clinical Study.. ESC heart failure. 2026. DOI: 10.1093/eschf/xvag175.