m+Medelevator.RU
← Поиск публикаций
Diagnostic microbiology and infectious disease · 2026

Diagnostic accuracy of bronchoalveolar lavage fluid-based testing for pulmonary cryptococcosis: A systematic review and meta-analysis.

СтатьяСистематический обзорМетаанализНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Tian Zongsheng, Sun Xueyan, Zhang Zuojuan, Du Qingdi, Xu Xueliang, Zeng Qingdi

Аннотация

BACKGROUND: Pulmonary cryptococcosis(PC) presents diagnostic challenges because of its non-specific clinical and radiological manifestations. Bronchoalveolar lavage fluid (BALF)-based testing, which includes latex agglutination (LA) and lateral flow assay (LFA), offers a minimally invasive diagnostic method, yet its pooled diagnostic accuracy remains unclear.

METHODS: We systematically searched PubMed, Embase, Cochrane Library, and Scopus from inception to May 2026. Studies evaluating BALF-based testing for PC with extractable 2 × 2 data were included. The methodological quality of relevant studies was assessed by the QUADAS-2 tool. Pooled sensitivity, specificity, likelihood ratios, and diagnostic odds ratio (DOR) were estimated using a bivariate random-effects model. Subgroup analyses were performed by testing method and reference standard type. Heterogeneity was evaluated through paired forest plots, HSROC visualization, and exploratory bivariate meta-regression.

RESULTS: The pooled sensitivity was 0.87 (95% CI: 0.81-0.91), and the specificity was 0.99 (95% CI: 0.982 - 0.995). The pooled positive likelihood ratio (PLR) was 88.00 (95% CI: 47.39 - 163.42), the negative likelihood ratio (NLR) was 0.13 (95% CI: 0.09 -0.20), and the DOR was 658.50 (95% CI: 285.36-1519.55). No significant threshold effect or publication bias was detected. Exploratory meta-regression suggested a possible assay-method effect in the joint model (P = 0.03), mainly driven by specificity (P = 0.01).

CONCLUSIONS: The study demonstrates the high accuracy of CrAg in BALF for the diagnosis of pulmonary cryptococcosis, supporting its role as an important adjunctive diagnostic tool, particularly when tissue biopsy is not feasible or rapid results are needed. Larger prospective studies with standardized protocols are needed to validate these estimates.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты