Background and

Objectives

Wearable health technologies have become increasingly important in the remote management of cardiovascular diseases (CVDs); however, their successful implementation depends not only on technical performance but also on patient usability and technology acceptance. This study aimed to evaluate the perceived usability and technology acceptance of a wearable monitoring system among patients with CVDs and to investigate whether demographic and clinical characteristics influenced these outcomes. Materials and

Methods

A cross-sectional observational study was conducted among 60 patients with CVDs enrolled in a six-month wearable monitoring program at the Medical Rehabilitation Outpatient Clinic of the Avram Iancu Clinical Hospital, Oradea, Romania. Participants used a Garmin vívosmart® 5 fitness tracker to continuously monitor physiological and behavioral parameters. At the end of the monitoring period, perceived ease of use (PEU) was assessed using the System Usability Scale (SUS), while technology acceptance was evaluated using a Technology Acceptance Model (TAM)-based questionnaire. Descriptive statistics, reliability analysis, Spearman's rank correlation, and multiple linear regression analyses were performed.

Results

The wearable monitoring system demonstrated high PEU, with a median SUS score of 82.5 (IQR = 23.1) and a mean score of 75.5 ± 17.6. Overall, 75.0% of participants rated the system as having good or excellent usability. The SUS questionnaire demonstrated acceptable internal consistency (Cronbach's α = 0.730; McDonald's ω = 0.741). Technology acceptance was generally favorable, with an overall median TAM-based score of 1.33 (IQR = 0.78). Age and comorbidity burden were not associated with PEU, and no participant characteristics independently predicted SUS scores. Although the overall regression model was not statistically significant, age showed a statistically significant association with the overall TAM-based score (β = 0.328, p = 0.037). Significant positive correlations were observed between PU, self-efficacy (SE), and reverse-scored technology anxiety (TA) measure (p < 0.001).

Conclusions

Patients with CVDs reported high PEU and favorable acceptance of wearable monitoring technology. While usability appeared independent of demographic and clinical characteristics, technology acceptance showed an exploratory association with age, although the overall regression model was not statistically significant. These findings support the integration of wearable monitoring systems into routine cardiovascular care and highlight the importance of patient-centered implementation strategies to promote long-term engagement.

Для цитирования: Morenci Marian, Iovanovici Diana Carina, Nistor Carmen Delia Cseppento, Tirla Sebastian, Karetka Anett Jolán, Mihuț Rareș Gheorghe, Tiboldi Akos, Lichtenegger Lisa, Bondar Laura Ioana, Jurca Tünde. Usability and Technology Acceptance of a Wearable Monitoring System Among Patients with Cardiovascular Diseases: A Cross-Sectional Study.. Medicina (Kaunas, Lithuania). 2026. DOI: 10.3390/medicina62081607.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.