m+Medelevator.RU
← Поиск публикаций
Translational vision science & technology · 2026

OptiDON-Guard: An Ensemble Model for Identification of Dysthyroid Optic Neuropathy Using Optical Coherence Tomography Angiography.

СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zhang Yanchen, Mao Yicheng, Zheng Jianming, Wang Lei, Wu Min, Zhao Jie, Li Zhixing, Liu Weibin, Zhou Shiguan, Wan Shuhui, Tu Yunhai, Wu Wencan, Yan Wentao

Аннотация

PURPOSE: To explore the value of machine learning models based on optical coherence tomography angiography (OCTA) in identifying dysthyroid optic neuropathy (DON).

METHODS: A retrospective, dual-center, cross-sectional study was conducted involving 346 thyroid eye disease patients (with/without DON) from two institutions. Participants underwent ophthalmic examinations, including OCTA scans centered on the macula and optic nerve head. The OCTA data from Center 1 were split into a training set and an internal validation set, while the data from Center 2 served as an external test set. Features were extracted from OCTA images, and a wrapper-based feature selection strategy identified the optimal subset. A two-tiered stacking modeling framework was used, incorporating baseline model construction, data augmentation using pseudo-labeling, and ensemble integration. Model performance (area under the curve [AUC], accuracy, sensitivity, specificity, precision) was evaluated alongside receiver operating characteristic, calibration, and decision curve analyses. Additionally, the SHapley Additive exPlanation method was used to interpret feature contributions.

RESULTS: The ensemble model, OptiDON-Guard, demonstrated superior performance to individual models on both internal validation and external test sets. In the internal validation set, it achieved an AUC of 0.872, accuracy of 0.943, sensitivity of 0.667, specificity of 0.979, and precision of 0.943. In the external test set, it maintained strong performance with an AUC of 0.854, accuracy of 0.816, sensitivity of 0.767, specificity of 0.842, and precision of 0.854.

CONCLUSIONS: The OptiDON-Guard is a reliable, interpretable, and clinically applicable tool for identifying DON.

TRANSLATIONAL RELEVANCE: The OptiDON-Guard offers a valuable clinical tool to enhance the diagnostic precision of DON.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты