MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ndt/12.12.2633

Медицинская библиотека · Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association · 1997

High bicarbonate dialysate in haemodialysis patients: effects on acidosis and nutritional status.

Williams A J, Dittmer I D, McArley A, Clarke J

Клиническое исследованиеКонтролируемое клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Metabolic acidosis adversely affects both protein and bone metabolism in patients with chronic renal failure, and could also affect morbidity and mortality. This trial aimed to investigate the effects of different dialysate bicarbonate concentrations on control of acid base balance, and nutritional status.

METHODS

Forty-six stable haemodialysis patients were dialysed using LowBic. (30 mmol/l) or HighBic. (40 mmol/l) bicarbonate dialysate in a single blind double crossover trial, of two consecutive six-month periods. Blood gas analysis, anthropometric indices and dialysis dose were measured, in addition to biochemical indices.

RESULTS

Predialysis 'arterial' plasma pH values were significantly higher when using the HighBic. dialysate (LowBic. 7.38 +/- 0.05, HighBic. 7.43 +/- 0.04, P < 0.001), as was predialysis serum total CO2 at all times during the study (P < 0.01). Kt/V, (LowBic. 1.27 +/- 0.19, HighBic. 1.27 +/- 0.25), urea generation rates (UGR) (LowBic. 1.99 +/- 0.77, HighBic. 1.92 +/- 0.77 mmol/min), and normalized protein catabolic rate (NPCR) (LowBic. 1.04 +/- 0.26, HighBic. 0.99 +/- 0.28 g/kg/day) did not differ, and values of parathroid hormone (PTH) were comparable. Triceps skinfold thickness (TSF) showed a significant change (LowBic. 14.8 +/- 6.9-11.8 +/- 5.5, HighBic. 14.9 +/- 6.3-15.8 +/- 6.4 mm, P < 0.05) which was reversed following dialysate change (HighBic. 11.8 +/- 5.5-13.3 +/- 7.2, LowBic. 15.8 +/- 6.4-13.8 +/- 6.7 mm, P < 0.05). No differences in mid upper arm circumference were found.

CONCLUSIONS

Bicarbonate dialysate concentrations of 40 mmol/l were safe, well tolerated, and produced better control of acidosis, with an increase in TSF, compared to a bicarbonate concentration of 30 mmol/l.

Для цитирования: Williams A J, Dittmer I D, McArley A, Clarke J. High bicarbonate dialysate in haemodialysis patients: effects on acidosis and nutritional status.. Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association. 1997. DOI: 10.1093/ndt/12.12.2633.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.