m+Medelevator.RU
← Поиск публикаций
Scientific reports · 2020

Radiation dose reduction for CT-guided intrathecal nusinersen administration in adult patients with spinal muscular atrophy.

Клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Cordts Isabell, Deschauer Marcus, Lingor Paul, Burian Egon, Baum Thomas, Zimmer Claus, Maegerlein Christian, Sollmann Nico

Аннотация

Intrathecal administration of nusinersen in adult spinal muscular atrophy (SMA) patients with scoliosis and spondylodesis requires image guidance, which is preferably achieved with multi-detector computed tomography (MDCT). As long-term treatment is necessary and patients are young, radiation doses should be reduced to a minimum whilst a sufficient image quality for precise interventional performance should be kept. We compared 44 MDCT standard-dose scans (133.0-200.0 mA) with a hybrid iterative reconstruction (iDose4) to 20 low-dose scans (20.0-67.0 mA) with iterative model reconstruction (IMR), which were performed for procedure planning of intrathecal nusinersen administration in 13 adult patients with SMA and complex spinal conditions. Qualitative image evaluation, including confidence for intervention planning, was performed by two neuroradiologists for standard- and low-dose scans. All 64 MDCT-guided intrathecal administrations of nusinersen were successful. The dose length product (DLP) was significantly lower when using low-dose scanning with IMR (median DLP of standard-dose scans: 92.0 mGy•cm vs. low-dose scans: 34.5 mGy•cm; p < 0.0001). Image quality was significantly reduced for low-dose compared to standard-dose scanning. However, bone/soft tissue contrast and confidence for intervention planning were not significantly impaired in low-dose MDCT according to both readers, showing good inter-reader agreement. Thus, we hereby demonstrate a low-dose MDCT protocol combined with advanced image reconstruction for scanning during procedure planning as a viable option for image guidance in intrathecal nusinersen treatment of adult SMA patients with complex spinal conditions.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты