MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0091-6749(95)70006-4

Медицинская библиотека · The Journal of allergy and clinical immunology · 1995

Laboratory evaluation of a commercial immunoassay for fire ant allergen-specific IgE antibodies.

Feger T A, Dolen W K, Ford J L, Ponder R D, Hoffman D R, Stafford C T

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

In vitro testing for fire ant sensitization would be useful for research purposes and in special clinical situations.

METHODS

Laboratory performance of a commercial assay (Pharmacia CAP System, [PCS]), for specific IgE to Solenopsis invicta whole body extract was studied in 46 persons. Assay results were compared with those of venom skin testing, RAST, and ELISA. The manufacturer's global cutoffs were compared with cutoffs set by using methods derived from analytical detection limit theory.

RESULTS

Thirty-two study subjects had positive skin test results, and 14 had negative results. Raw PCS data demonstrated a high level of correlation with RAST (rho = 0.941) and ELISA (rho = 0.931), and showed good correlation with skin testing (rho = -0.769). Analysis of binormal receiver operating characteristic curves, using skin test results as the reference standard, demonstrated no difference in performance among the three assays. The fixed global quantitative cutoff of 0.35 kUa/L was relatively insensitive. Use of the manufacturer's qualitative alternate scoring method cutoff substantially increased sensitivity without loss of specificity, as did lower limit of detection set by use of diluent.

CONCLUSIONS

In situations in which skin testing for fire ant sensitization is not feasible, PCS appears to be an acceptable in vitro alternative method for determination of fire ant allergen-specific IgE.

Для цитирования: Feger T A, Dolen W K, Ford J L, Ponder R D, Hoffman D R, Stafford C T. Laboratory evaluation of a commercial immunoassay for fire ant allergen-specific IgE antibodies.. The Journal of allergy and clinical immunology. 1995. DOI: 10.1016/s0091-6749(95)70006-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.