Predicting the benefit of adaptive radiotherapy in head and neck Cancer using cone-beam computed tomography.

Lee Donghoon, Aristophanous Michalis, Lichtenwalner Phillip, Abraham Shira, Donahue William, Nehmeh Mohammad, Caringi Amanda, Zhang Peng, Hu Yu-Chi, Zhang Pengpeng, Cerviño Laura, Gelblum Daphna, McBride Sean, Riaz Nadeem, Chen Linda, Yu Yao, Zakeri Kaveh, Lee Nancy, Aliotta Eric

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: Adaptive radiotherapy for head and neck cancer is resource-intensive, and existing geometric triggers lack a quantitative dose basis. We developed a model based on dose differences derived from cone-beam computed tomography to predict adaptive radiotherapy benefit.

MATERIALS AND

METHODS

Seventy-four patients with head and neck cancer treated with sequential-phase intensity-modulated radiotherapy and offline adaptive radiotherapy were analyzed. Patients were labeled as high or low adaptive radiotherapy benefit by k-means clustering of dose features derived from the resimulation computed tomography. A multivariable logistic regression classifier was trained on percent mean dose differences measured on the week 3 cone-beam computed tomography for five normal tissues (both parotid glands, both submandibular glands, and the oral cavity) and evaluated by leave-one-out cross-validation, alongside a parallel classifier using normal tissue volume changes.

RESULTS

Dose differences correlated with adaptive radiotherapy benefit for all five normal tissues (Spearman ρ s = -0.76 to -0.43; all p < 0.01, Jonckheere-Terpstra trend test), whereas volume changes showed no significant association (all p > 0.10). The dose model achieved an area under the receiver operating characteristic curve of 0.78 versus 0.54 for the volume model. On univariate analysis the ipsilateral parotid gland was the strongest single-organ predictor, whereas the multivariable model assigned the largest standardized coefficient to the ipsilateral submandibular gland, reflecting collinearity between the parotid glands.

CONCLUSIONS

Dose differences derived from cone-beam computed tomography provide an objective, quantitative basis for predicting adaptive radiotherapy benefit in head and neck cancer, offering a practical alternative to geometric triggers and supporting selective, resource-efficient adaptation.

Для цитирования: Lee Donghoon, Aristophanous Michalis, Lichtenwalner Phillip, Abraham Shira, Donahue William, Nehmeh Mohammad, Caringi Amanda, Zhang Peng, Hu Yu-Chi, Zhang Pengpeng, Cerviño Laura, Gelblum Daphna, McBride Sean, Riaz Nadeem, Chen Linda, Yu Yao, Zakeri Kaveh, Lee Nancy, Aliotta Eric. Predicting the benefit of adaptive radiotherapy in head and neck Cancer using cone-beam computed tomography.. Physics and imaging in radiation oncology. 2026. DOI: 10.1016/j.phro.2026.101069.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.