MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/rct.0000000000001727

Медицинская библиотека · Journal of computer assisted tomography · 2025

High-resolution 0.25 mm Detector CT Has Limited Impact on Right Adrenal Vein Detectability in Preprocedural Contrast Enhanced CT for Adrenal Venous Sampling.

Morisaka Hiroyuki, Imaizumi Akira, Wumu Tihan, Ii Takanori, Araki Takuji, Onishi Hiroshi

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

This study aims to identify factors associated with the detectability of the right adrenal vein (RAV) on preoperative contrast-enhanced CT scans of adrenal venous sampling (AVS) in the era of high-resolution CT (HRCT).

MATERIALS AND

METHODS

In this retrospective study, 36 patients (15 men and 21 women; mean age, 56 y) who underwent preoperative contrast-enhanced CT [11 patients in HRCT with 0.25 mm detector matrix (Cannon Medical Systems) and 25 patients in conventional multidetector CT with 0.5 mm matrix] were included. A contrast agent dose of 600 mgI/kg was injected, and CT images were acquired at a fixed scan delay of 50 and 80 seconds. Adrenal venography and venous sampling were performed for the diagnosis of suspected primary hyperaldosteronism. The qualitative detectability of RAV on preoperative CT was assessed with adrenal venography as a reference. Clinical and imaging factors associated with a good detectability of RAV were analyzed via regression analysis. Optimal acquisition timing was assessed by analyzing the time-intensity curve and contrast enhancement pattern of the inferior vena cava using CT data from a separate cohort (n=5).

RESULTS

The qualitative detectability of RAV was deemed good in 15 patients and poor in 21 patients. Regression analysis revealed that only heterogeneous enhancement of inferior vena cava with bolus high attenuation, corresponding to an optimal acquisition timing from time-intensity curve analysis, was associated with a good detectability of RAV (odds ratio, 5.06). The use of HRCT was not statistically significant.

CONCLUSIONS

Optimal acquisition timing is a crucial factor for the detectability of RAV in preprocedural CT for AVS, while high-resolution 0.25 detector CT appears to have limited significance.

Для цитирования: Morisaka Hiroyuki, Imaizumi Akira, Wumu Tihan, Ii Takanori, Araki Takuji, Onishi Hiroshi. High-resolution 0.25 mm Detector CT Has Limited Impact on Right Adrenal Vein Detectability in Preprocedural Contrast Enhanced CT for Adrenal Venous Sampling.. Journal of computer assisted tomography. 2025. DOI: 10.1097/rct.0000000000001727.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.