m+Medelevator.RU
← Поиск публикаций
Journal of the American College of Radiology : JACR · 2025

Validating Radiology Artificial Intelligence Model Performance on Photon-Counting CT Images Using Large Language Models for Ground Truth Extraction.

СтатьяВалидационное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ng Yee Seng, Kanani Mohammed M, King William E, Miller Zachary D, Brown Lauryn, Wishart Joey, Lindgren-Ruby Alex, Medverd Jonathan R, Cross Nathan M

Аннотация

PURPOSE: The aim of this study was to evaluate the feasibility of using large language models (LLMs) to automate ground truth label extraction from radiology reports, enabling scalable assessment and monitoring of radiologic artificial intelligence (AI) tools. The framework was tested by validating AI model performance on a newly installed photon-counting CT (PCCT) scanner.

METHODS: Four FDA-cleared deep learning-based computer-aided detection and triage tools targeting pulmonary embolism, intracranial hemorrhage, cervical spinal fractures, and vertebral compression fractures were retrospectively analyzed. Radiology reports from examinations acquired using the new PCCT scanner and conventional scanners were processed using an LLM (Llama 3.3) to extract binary ground truth labels. AI outputs were compared with these labels to estimate performance metrics. Discrepant cases were adjudicated by three human annotators, with interrater reliability measured using Fleiss's κ test. Performance metrics were recalculated after partial human correction of LLM errors.

RESULTS: LLM-extracted labels enabled rapid performance assessment across all four diagnostic tasks. There were no statistically significant differences in performance between the PCCT and non-PCCT cohorts. In discrepant cases, the agreement between LLM labels and final human annotations (κ = 0.731) was comparable with interreader agreement (κ = 0.720), supporting the reliability of LLM labeling.

CONCLUSIONS: LLMs can be used to automate ground truth label extraction from radiology reports, offering a scalable and efficient alternative to manual annotation. This method supports rapid local validation of AI tools, even in response to input drift from new imaging hardware.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты