MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1056/nejm198910053211404

Медицинская библиотека · The New England journal of medicine · 1989

111In-labeled nonspecific immunoglobulin scanning in the detection of focal infection.

Rubin R H, Fischman A J, Callahan R J, Khaw B A, Keech F, Ahmad M, Wilkinson R, Strauss H W

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

We performed radionuclide scanning after the intravenous injection of human IgG labeled with indium-111 in 128 patients with suspected focal sites of inflammation. Localization of 111In-labeled IgG correlated with clinical findings in 51 infected patients (21 with abdominal or pelvic infections, 11 with intravascular infections, 7 with pulmonary infections, and 12 with skeletal infections). Infecting organisms included gram-positive bacteria, gram-negative bacteria, Pneumocystis carinii, Mycoplasma pneumoniae, and Candida albicans. No focal localization of 111In-labeled IgG was observed in 63 patients without infection. There were five false negative results, and nine results were unusable. Serial scans were carried out in eight patients: continued localization correctly predicted relapse in six, and the absence of localization indicated resolution in two. To determine whether 111In-labeled IgG localization was specific for inflammation, we studied 16 patients with cancer. Focal localization occurred in 13 of these patients (5 with melanomas, 5 with gynecologic cancers, and 1 each with lymphoma, prostate cancer, and malignant fibrous histiocytoma). No localization was seen in patients with renal or colon cancer or metastatic medullary carcinoma of the thyroid. We conclude that 111In-labeled IgG imaging is effective for the detection of focal infection and that serial scans may be useful in assessing therapeutic efficacy. This technique may also be helpful in the evaluation of certain cancers.

Для цитирования: Rubin R H, Fischman A J, Callahan R J, Khaw B A, Keech F, Ahmad M, Wilkinson R, Strauss H W. 111In-labeled nonspecific immunoglobulin scanning in the detection of focal infection.. The New England journal of medicine. 1989. DOI: 10.1056/nejm198910053211404.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.