International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group · 2013

Uterine myomas treated with microwave ablation: the agreement between ablation volumes obtained from contrast-enhanced sonography and enhanced MRI.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Lei Feng, Jing Zhang, Bo Wen, Dongmei Hu, Zhencai Li, Xue Jiang, Fang Wang, Hongyu Zhou, Jintao Ren

Аннотация

PURPOSE: This study explores the agreement between ablated uterine myoma volumes obtained from contrast-enhanced sonography and enhanced magnetic resonance imaging (MRI) after microwave ablation therapy.

MATERIALS AND METHODS: Twenty uterine myomas in 18 patients (average size: 5.56 ± 1.26 cm) were successfully treated by microwave ablation. Contrast-enhanced sonography and enhanced MRI were performed within 7 days after the treatment. The ablation range of uterine myomas was observed and the ablation volume was calculated. By using the intraclass correlation coefficient (ICC) and Bland-Altman regression analysis, the agreement between ablated uterine myoma volumes obtained from contrast-enhanced sonography and enhanced MRI after microwave ablation therapy was analysed.

RESULTS: The ablated volume ranged from 13.66 to 135.27 cm(3) after ablation, and the mean volume was 66.59 ± 35.71 cm(3) by using contrast-enhanced sonography. Respectively, the ablated volume ranged from 10.88 to 137.83 cm(3), and the mean volume was 66.81 ± 35.45 cm(3) by using enhanced MRI. The limits of agreement between the two methods were (-10.83 cm(3), 8.39 cm(3)), ICC was 0.991 (F = 209.61, P < 0.05), and 95% confidence interval is (0.976, 0.996). The results revealed a good agreement between the two examination methods of contrast-enhanced sonography and enhanced MRI.

CONCLUSIONS: Contrast-enhanced sonography and enhanced MRI can be used interchangeably in observing the ablation range of uterine myomas treated with microwave ablation. Contrast-enhanced sonography can be used as a preferred non-invasive examination and for follow-up. Meanwhile, enhanced MRI can be used to comprehensively determine the relationships among uterine myomas, the entire uterus, and surrounding tissues.