MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/cyto.b.20104

Медицинская библиотека · Cytometry. Part B, Clinical cytometry · 2006

Detection of rabies virus antigen or antibody using flow cytometry.

Vengatesan Dayalan, Raj Gopal Dhinakar, Raja Angamuthu, Ramadass Pachaikani, Gunaseelan Lakshmanaswamy

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Rabies is invariably a fatal encephalomyelitis that is considered to be a serious public health problem. Rabies diagnosis must be rapid and conclusive. Detection and quantification of antirabies antibodies is used for assessment of the effectiveness of rabies vaccines. Hence, computer-automated detection of fluorescence using flow cytometry was attempted to reduce the work time required to undertake the conventional rapid fluorescent focus inhibition test (RFFIT).

METHODS

Pasteur virus (PV)-infected mouse neuroblastoma (MNA) cells were stained with rabies virus antinucleocapsid antibody, fluorescein isothiocyanate (FITC) conjugate, and the percentage of infected cells at 24, 48, and 72 h postinfection (PI) was determined using flow cytometry. Serum samples containing known antibody titres estimated by RFFIT in terms of IU/ml were used to neutralize 50 FFD50 dose of PV. The percentage of MNA cells infected by the un-neutralized virus was estimated by flow cytometry. Using the value of the percentage of cells infected in the presence of known negative serum as 100%, the infection inhibition caused by antibodies at each dilution of positive reference serum was calculated and a regression equation generated for the prediction of rabies virus antibody titres in test sera samples as equivalent units per ml (EU/ml).

RESULTS

There was a significant increase in the percentage of infected cells between 24 and 48 h PI from 26.45 to 75.28%. The percentage of cells having high side scatter was also highest at 72 h PI (11.11%). Antibody titres predicted by flow cytometry and those estimated by RFFIT as IU/ml showed a correlation coefficient of 0.74.

CONCLUSIONS

Thus, flow cytometry could be used to detect rabies virus antigen in infected cells and to predict serum antibody titres from a single dilution of serum tested with the potential advantages of automation, rapidity, and lack of subjectivity. It has the potential to replace the time-tested RFFIT in rabies serology in the years to come.

Для цитирования: Vengatesan Dayalan, Raj Gopal Dhinakar, Raja Angamuthu, Ramadass Pachaikani, Gunaseelan Lakshmanaswamy. Detection of rabies virus antigen or antibody using flow cytometry.. Cytometry. Part B, Clinical cytometry. 2006. DOI: 10.1002/cyto.b.20104.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.