Transoral robotic cordectomy for glottic carcinoma: a rapid review.

Lechien Jérôme R, Baudouin Robin, Circiu Marta P, Chiesa-Estomba Carlos M, Crevier-Buchman Lise, Hans Stephane

СтатьяОбзорПеревод пока не подготовлен

Аннотация

OBJECTIVE

The objective of this study was to investigate feasibility, surgical, oncological, and functional outcomes of transoral robotic cordectomy (TORS-Co) and whether TORS-Co reported comparable outcomes of transoral laser microsurgery (TLM).

METHODS

PubMed, Scopus, and Cochrane Library were searched by three laryngologists for studies investigating feasibility, surgical, oncological, and functional outcomes of patients benefiting from TORS-Co. The following outcomes were investigated according to the PRISMA statements: age; cT stage; types of cordectomy; surgical settings; complications; and functional and feasibility features.

RESULTS

Nine studies published between 2009 and 2021 met our inclusion criteria, accounting for 114 patients. There was no controlled study. TORS-Co was performed in cT1 or cT2 glottic cancer through types II, III, IV, V, or VI cordectomies. The exposure was inadequate in 4% of cases, leading to conversion in transoral laser cordectomy. Margins were positive in 4.5% and local recurrence occurred in 10.7% (N = 8/75). Tracheotomy and feeding tube requirement varied across studies, depending on the types of TORS-Co. The mean duration of robot installation/vocal cord exposure and operative times ranged from 20 to 42 min and 10 to 40 min, respectively. The mean duration of hospital stay ranged from 2 to 7 days. Complications included dyspnea, bleeding, granuloma, synechia, and tongue hematoma and dysesthesia.

CONCLUSION

The current robotic systems do not appear adequate for TORS-Co. TORS-Co was associated with higher rates of complications and tracheotomy than TLM.

Для цитирования: Lechien Jérôme R, Baudouin Robin, Circiu Marta P, Chiesa-Estomba Carlos M, Crevier-Buchman Lise, Hans Stephane. Transoral robotic cordectomy for glottic carcinoma: a rapid review.. European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery. 2022. DOI: 10.1007/s00405-022-07514-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.