MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11547-024-01898-5

Медицинская библиотека · La Radiologia medica · 2024

Dual-energy CT late arterial phase iodine maps for the diagnosis of acute non-occlusive mesenteric ischemia.

D'Angelo Tommaso, Bucolo Giuseppe M, Yel Ibrahim, Koch Vitali, Gruenewald Leon D, Martin Simon S, Alizadeh Leona S, Vogl Thomas J, Ascenti Giorgio, Lanzafame Ludovica R M, Mazziotti Silvio, Blandino Alfredo, Booz Christian

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the diagnostic accuracy of dual-energy CT (DECT) iodine maps in comparison to conventional CT series for the assessment of non-occlusive mesenteric ischemia (NOMI).

MATERIAL AND

METHODS

We evaluated data from 142 patients (72 men; 50.7%) who underwent DECT between 2018 and 2022, with surgically confirmed diagnosis of NOMI. One board-certified radiologist performed region of interest (ROI) measurements in bowel segments on late arterial (LA) and portal venous (PV) phase DECT iodine maps as well as LA conventional series, in both ischemic and non-ischemic bowel loops, using surgical reports as reference standard, and in a control group of 97 patients. Intra- and inter-reader agreement with a second board-certified radiologist was also evaluated. Receiver operating characteristic (ROC) curve analysis was performed to calculate the optimal threshold for discriminating ischemic from non-ischemic bowel segments. Subjective image rating of LA and PV iodine maps was performed.

RESULTS

DECT-based iodine concentration (IC) measurements showed significant differences in LA phase iodine maps between ischemic (median:0.72; IQR 0.52-0.91 mg/mL) and non-ischemic bowel loops (5.16; IQR 3.45-6.31 mg/ml) (P <.0001). IC quantification on LA phase revealed an AUC of 0.966 for the assessment of acute bowel ischemia, significantly higher compared to both IC quantification based on PV phase (0.951) and attenuation values evaluated on LA conventional CT series (0.828). Excellent intra-observer and strong inter-observer agreements were observed for the quantification of iodine concentration. Conversely, weak inter-observer agreement was noted for conventional HU assessments. The optimal LA phase-based IC threshold for assessing bowel ischemia was 1.34 mg/mL, yielding a sensitivity of 100% and specificity of 96.48%.

CONCLUSION

Iodine maps based on LA phase significantly improve the diagnostic accuracy for the assessment of NOMI compared to conventional CT series and PV phase iodine maps.

Для цитирования: D'Angelo Tommaso, Bucolo Giuseppe M, Yel Ibrahim, Koch Vitali, Gruenewald Leon D, Martin Simon S, Alizadeh Leona S, Vogl Thomas J, Ascenti Giorgio, Lanzafame Ludovica R M, Mazziotti Silvio, Blandino Alfredo, Booz Christian. Dual-energy CT late arterial phase iodine maps for the diagnosis of acute non-occlusive mesenteric ischemia.. La Radiologia medica. 2024. DOI: 10.1007/s11547-024-01898-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.