MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1515/raon-2015-0008

Медицинская библиотека · Radiology and oncology · 2015

Clinical applicability of biologically effective dose calculation for spinal cord in fractionated spine stereotactic body radiation therapy.

Lee Seung Heon, Lee Kyu Chan, Choi Jinho, Ahn So Hyun, Lee Seok Ho, Sung Ki Hoon, Kil Se Hee

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The aim of the study was to investigate whether biologically effective dose (BED) based on linear-quadratic model can be used to estimate spinal cord tolerance dose in spine stereotactic body radiation therapy (SBRT) delivered in 4 or more fractions.

PATIENTS AND

METHODS

Sixty-three metastatic spinal lesions in 47 patients were retrospectively evaluated. The most frequently prescribed dose was 36 Gy in 4 fractions. In planning, we tried to limit the maximum dose to the spinal cord or cauda equina less than 50% of prescription or 45 Gy2/2. BED was calculated using maximum point dose of spinal cord.

RESULTS

Maximum spinal cord dose per fraction ranged from 2.6 to 6.0 Gy (median 4.3 Gy). Except 4 patients with 52.7, 56.4, 62.4, and 67.9 Gy2/2, equivalent total dose in 2-Gy fraction of the patients was not more than 50 Gy2/2 (12.1-67.9, median 32.0). The ratio of maximum spinal cord dose to prescription dose increased up to 82.2% of prescription dose as epidural spinal cord compression grade increased. No patient developed grade 2 or higher radiation-induced spinal cord toxicity during follow-up period of 0.5 to 53.9 months.

CONCLUSIONS

In fractionated spine SBRT, BED can be used to estimate spinal cord tolerance dose, provided that the dose per fraction to the spinal cord is moderate, e.g. < 6.0 Gy. It appears that a maximum dose of up to 45-50 Gy2/2 to the spinal cord is tolerable in 4 or more fractionation regimen.

Для цитирования: Lee Seung Heon, Lee Kyu Chan, Choi Jinho, Ahn So Hyun, Lee Seok Ho, Sung Ki Hoon, Kil Se Hee. Clinical applicability of biologically effective dose calculation for spinal cord in fractionated spine stereotactic body radiation therapy.. Radiology and oncology. 2015. DOI: 10.1515/raon-2015-0008.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.