MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/oby.22675

Медицинская библиотека · Obesity (Silver Spring, Md.) · 2020

Comparison of Anthropometric Measures in US Military Personnel in the Classification of Overweight and Obesity.

Shams-White Marissa M, Chui Kenneth, Deuster Patricia A, McKeown Nicola M, Must Aviva

СтатьяПоддержка правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

This study aimed to determine (1) the level of agreement between BMI, circumference-based equation (CBE) measures, waist circumference (WC), and bioelectrical impedance analysis (BIA) measures and (2) whether BMI, CBE measures, or WC alone or in combination adequately reflects adiposity in military personnel compared with BIA.

METHODS

BMI from measured height and weight (using military overweight cutoffs in men [BMI ≥ 27.5 kg/m2 ] and World Health Organization overweight cutoffs [BMI ≥ 25.0 kg/m2 ]), BMI body fat percentage (BF%), WC, CBE BF%, and BIA BF% were collected. Respondents (N = 389, 78% men) were categorized with normal fat versus overweight, obesity, or overfat. Levels of agreement and standard screening performance measures were compared between anthropometric measures and BIA.

RESULTS

World Health Organization BMI and BIA BF% classified the most men and women with overweight/obesity; WC with BMI (BMI + WC) and WC alone classified the fewest men and women with overweight/obesity. Levels of agreement were all statistically significant and highest for BMI (men: Cohen's κ = 0.711; women: Cohen's κ = 0.814) and lowest for WC and BMI + WC (all Cohen's κ ≤ 0.270). BMI + CBE performed best overall (sensitivity = 50.9%, false discovery rate = 5.4%).

CONCLUSIONS

Our findings support BMI + CBE as an easy-to-implement combination to assess adiposity in the military.

Для цитирования: Shams-White Marissa M, Chui Kenneth, Deuster Patricia A, McKeown Nicola M, Must Aviva. Comparison of Anthropometric Measures in US Military Personnel in the Classification of Overweight and Obesity.. Obesity (Silver Spring, Md.). 2020. DOI: 10.1002/oby.22675.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.