m+Medelevator.RU
← Поиск публикаций
Abdominal radiology (New York) · 2022

Computed diffusion-weighted magnetic resonance imaging with high b-values in the diagnosis of gallbladder lesions.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Sato Motokazu, Kurita Yusuke, Sakai Eiji, Watanabe Seitaro, Sanada Haruto, Shimizu Tomoki, Kanoshima Kenji, Takai Yusuke, Meguro Koki, Sugimoto Yuichi, Biwata Yusuke, Hosono Kunihiro, Kobayashi Noritoshi, Kubota Kensuke, Nakajima Atsushi

Аннотация

PURPOSE: The diagnosis of gallbladder lesions remains challenging. The efficacy of computed diffusion-weighted imaging (DWI) with high b-values and apparent diffusion coefficient (ADC) for the diagnosis of gallbladder cancer remains unknown. We aimed to investigate the usefulness of computed DWI with high b-values and the combination of computed DWI and ADC in differentiating malignant and benign gallbladder lesions.

METHODS: Sixty patients (comprising 30 malignant and 30 benign lesions) who underwent magnetic resonance imaging for gallbladder lesions were included in this retrospective study. Qualitative evaluations were performed using conventional DWI with b1000, computed DWI with b1500, b1000 DWI/ADC, and computed b1500 DWI/ADC, and their diagnostic performances were compared.

RESULTS: The sensitivity, specificity, and accuracy of computed b1500 DWI/ADC were 90% (27/30), 80% (24/30), and 85% (51/60), respectively. The accuracy of computed b1500 DWI/ADC was higher than that of conventional b1000 DWI (52%, 31/60, p < 0.001), computed b1500 DWI (72%, 43/60, p = 0.008), and b1000 DWI/ADC (78%, 47/60, p = 0.125). The specificity of computed b1500 DWI/ADC was also higher than that of conventional b1000 DWI (7%, 2/30, p < 0.001), computed b1500 DWI (47%, 14/30, p = 0.002), and b1000 DWI/ADC (67%, 20/30, p = 0.125). No significant difference was observed in the sensitivity between the groups.

CONCLUSION: This study shows that computed DWI with high b-values combined with ADC can improve diagnostic performance when differentiating malignant and benign gallbladder lesions. Computed diffusion-weighted magnetic resonance imaging with high b-values in the diagnosis of gallbladder lesions. *Computed DWI with b1500 combined with ADC can improve diagnostic performance when differentiating gallbladder lesions compared with conventional methods (b1000 DWI).

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты