MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2460/javma.25.02.0082

Медицинская библиотека · Journal of the American Veterinary Medical Association · 2025

Similar performance between modified retrobulbar and ultrasound-guided Peterson nerve blocks using computed tomography in bovine cadavers.

Bayne Jenna E, Cole Robert C

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Description and performance of an ultrasound-guided Peterson (UP) block technique were compared to those of a conventional modified retrobulbar (RB) nerve block in bovine cadaver heads by use of CT.

METHODS

This was an original descriptive study using 10 normal orbits from 5 bovid cadavers between April 17 and 23, 2024. Standardized techniques for the modified RB and UP blocks were utilized, with each technique randomly performed on either orbit of each head. Blocks were performed with 9-cm, 18-gauge spinal needles and iopamidol as a contrast solution. Ultrasound guidance involved the use of a 12-MHz linear transducer, and subsequent imaging of contrast distribution was performed with a GE Lightspeed 16-slice CT scanner.

RESULTS

Contrast deposition within the intraconal space was observed in 5 of 5 RB blocks and 5 of 5 UP blocks. No extraconal contrast deposition was observed in either block technique. Extension of contrast in close association with the optic nerve to the level of orbital foramen was observed in 5 of 5 RB orbits and 5 of 5 UP orbits. Extension of the contrast to the level of the foramen orbitorotundum was seen in 5 of 5 RB orbits and 3 of 5 UP orbits. Correct needle placement was observed in 5 of 5 UP orbits and confirmed on CT images.

CONCLUSIONS

The RB and UP blocks performed similarly, demonstrating similar intraconal distribution of contrast medium and no inadvertent distribution to unintended anatomical locations.

CLINICAL RELEVANCE: The performance of the ultrasound-guided technique in live cattle and ability to successfully achieve adequate blockade need further study.

Для цитирования: Bayne Jenna E, Cole Robert C. Similar performance between modified retrobulbar and ultrasound-guided Peterson nerve blocks using computed tomography in bovine cadavers.. Journal of the American Veterinary Medical Association. 2025. DOI: 10.2460/javma.25.02.0082.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.