MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/17434440.2020.1741349

Медицинская библиотека · Expert review of medical devices · 2020

Can we reduce conduction disturbances following transcatheter aortic valve replacement?

Alperi Garcia Alberto, Muntané-Carol Guillem, Junquera Lucia, Del Val David, Faroux Laurent, Philippon François, Rodés-Cabau Josep

СтатьяОбзорПеревод пока не подготовлен

Аннотация

Introduction

Transcatheter aortic valve replacement (TAVR) has been demonstrated to be a good alternative to surgery for treating severe aortic stenosis (AS) across the whole range of surgical risk patients. Whereas most periprocedural TAVR complications have significantly decreased over time, conduction disturbances remain high. Approaches to decrease this shortcoming are under continuous investigation.Areas covered: Overview of the actual evidence regarding conduction disturbances in the TAVR setting, focusing on modifiable factors. PubMed and Embase databases were used for literature search.Expert opinion: Several factors have been associated with an increased risk of conduction disturbances post-TAVR, and some of them may be modifiable. While some transcatheter valve systems have been associated with higher rates of conduction disturbances, additional randomized data are needed to draw definite conclusions about newer generation transcatheter valve systems. Nowadays, good hemodynamic valve function can be obtained without excessive valve oversizing, which has been associated with an increased risk of conduction disturbances in some studies. Also, contemporary data regarding valve implantation depth and new anatomical landmarks such as membranous septum length have provided valuable insights for procedural planning. Finally, homogenization of the management of conduction abnormalities post-TAVR should be emphasized to allow a better understanding and generalization of available evidence.

Для цитирования: Alperi Garcia Alberto, Muntané-Carol Guillem, Junquera Lucia, Del Val David, Faroux Laurent, Philippon François, Rodés-Cabau Josep. Can we reduce conduction disturbances following transcatheter aortic valve replacement?. Expert review of medical devices. 2020. DOI: 10.1080/17434440.2020.1741349.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.