The influence of scar on the spatio-temporal relationship between electrical and mechanical activation in heart failure patients.
Аннотация
AIMS: The aim of this study was to determine the relationship between electrical and mechanical activation in heart failure (HF) patients and whether electromechanical coupling is affected by scar.
METHODS AND
RESULTS
Seventy HF patients referred for cardiac resynchronization therapy or biological therapy underwent endocardial anatomo-electromechanical mapping (AEMM) and delayed-enhancement magnetic resonance (CMR) scans. Area strain and activation times were derived from AEMM data, allowing to correlate mechanical and electrical activation in time and space with unprecedented accuracy. Special attention was paid to the effect of presence of CMR-evidenced scar. Patients were divided into a scar (n = 43) and a non-scar group (n-27). Correlation between time of electrical and mechanical activation was stronger in the non-scar compared to the scar group [R = 0.84 (0.72-0.89) vs. 0.74 (0.52-0.88), respectively; P = 0.01]. The overlap between latest electrical and mechanical activation areas was larger in the absence than in presence of scar [72% (54-81) vs. 56% (36-73), respectively; P = 0.02], with smaller distance between the centroids of the two regions [10.7 (4.9-17.4) vs. 20.3 (6.9-29.4) % of left ventricular radius, P = 0.02].
CONCLUSION
Scar decreases the association between electrical and mechanical activation, even when scar is remote from late activated regions.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.