m+Medelevator.RU
← Поиск публикаций
The Israel Medical Association journal : IMAJ · 2019

The Utility of Prophylactic Pacemaker Implantation in Right Bundle Branch Block Patients Pre-Transcatheter Aortic Valve Implantation.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Tovia-Brodie Oholi, Letourneau-Shesaf Sevan, Hochstadt Aviram, Steinvil Arie, Rosso Raphael, Finkelstein Ariel, Michowitz Yoav

Аннотация

BACKGROUND: Patients with right bundle branch block (RBBB) prior to transcatheter aortic valve implantation (TAVI) are at high risk for immediate post-procedural heart block and long-term mortality when discharged without a pacemaker.

OBJECTIVES: To test whether prophylactic permanent pacemaker implantation (PPI) is beneficial.

METHODS: Of 795 consecutive patients who underwent TAVI, 90 patients had baseline RBBB. We compared characteristics and outcomes of the prophylactic PPI with post-TAVI PPI. Need for pacing was defined as  greater than 1% ventricular pacing.

RESULTS: Forty patients with RBBB received a prophylactic PPI (group 1), and in 50 the decision was based on standard post-procedural indications (group 2). There were no significant differences in clinical baseline characteristics. One patient developed a tamponade after a PPI post-TAVI. A trend toward shorter hospitalization duration in group 1 patients was observed (P = 0.06). On long-term follow-up of 848 ± 56 days, no differences were found in overall survival (P = 0.77), the composite event-free survival of both mortality and hospitalizations (P = 0.66), or mortality and syncope (P = 0.65). On multivariate analysis, independent predictors of the need for pacing included baseline PR interval increase of 10ms (odds ratio [OR] 1.21 per 10 ms increment 95% confidence interval [95%CI] 1.02-1.44, P = 0.028), and the use of new generation valves (OR 3.92, 95%CI 1.23-12.46, P = 0.023).

CONCLUSIONS: In patients with baseline pre-TAVI RBBB, no outcome differences were found with prophylactic PPI. On multivariate analysis, predictors of the need for pacing included baseline long PR interval, and the use of newer generation valves.