Comparison of measures of ventricular delay on cardiac resynchronization therapy response.

Field Michael E, Yu Nancy, Wold Nicholas, Gold Michael R

СтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Left ventricular (LV) pacing at sites of prolonged LV delay (QLV) or at long interventricular delay (right ventricle [RV]-LV) is strongly associated with cardiac resynchronization therapy (CRT) response. QLV and RV-LV have been independently evaluated, but little is known regarding the interrelationship between these measures or of delay to the RV.

OBJECTIVE

The purpose of this study was to evaluate the relationship between measures of electrical delay on CRT response in the SMART-AV (SmartDelay Determined AV Optimization: A Comparison to Other AV Delay Methods Used in Cardiac Resynchronization Therapy) trial.

METHODS

In 419 patients, QLV and RV-LV were measured. CRT response was defined as a >15% reduction in LV end-systolic volume from implant to 6 months. The correlation between QLV and RV-LV and the clinical variables associated with the difference between QLV and RV-LV (QRV) were determined. Multivariable logistic regression was used to analyze the association between these measures on CRT response. A machine learning algorithm was used to construct a classification tree to predict response to CRT.

RESULTS

The cohort was 66% male (age 66 ± 11 years), 75% had left bundle branch block; and QRS was 150 ± 25 ms. QLV and RV-LV were highly correlated (R2 = 0.71). A longer QRV was observed among patients with right bundle branch block, ischemic cardiomyopathy, and increased QRS. In a multivariable model including QLV, RV-LV, and other known predictors of CRT response, RV-LV, but not QLV, remained associated with CRT response (odds ratio 1.13; 95% confidence interval 1.02-1.26; P = .017). Combining the 2 measures achieved better prediction of CRT response in the group with intermediate RV-LV.

CONCLUSION

RV-LV is a better predictor of CRT response than QLV. There is incremental value in using both measurements or QRV in certain subpopulations.

Для цитирования: Field Michael E, Yu Nancy, Wold Nicholas, Gold Michael R. Comparison of measures of ventricular delay on cardiac resynchronization therapy response.. Heart rhythm. 2019. DOI: 10.1016/j.hrthm.2019.11.023.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.