MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1253/circj.cj-19-0691

Медицинская библиотека · Circulation journal : official journal of the Japanese Circulation Society · 2019

Efficacy of a Device-Based Continuous Optimization Algorithm for Patients With Cardiac Resynchronization Therapy.

Ueda Nobuhiko, Noda Takashi, Ishibashi Kohei, Nakajima Kenzaburo, Kataoka Naoya, Kamakura Tsukasa, Wada Mitsuru, Yamagata Kenichiro, Inoue Yuko, Miyamoto Koji, Nagase Satoshi, Aiba Takeshi, Kanzaki Hideaki, Izumi Chisato, Noguchi Teruo, Yasuda Satoshi, Kusano Kengo

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Cardiac resynchronization therapy (CRT) is less effective in patients with mildly wide QRS or non-left bundle branch block (non-LBBB). A new algorithm of every minute's optimization (adaptive CRT: aCRT algorithm) is effective in patients with CRT devices. This study investigated the clinical effect of the aCRT algorithm, especially in mildly wide QRS (120≤QRS<150 ms) or non-LBBB patients receiving CRT.

METHODS AND

RESULTS

This study included 104 CRT patients (48 patients using the aCRT algorithm [adaptive group] and 56 patients not using the aCRT algorithm [non-adaptive group]). The primary endpoint was a composite clinical outcome of cardiac death and/or heart failure (HF) hospitalization. During a median follow-up of 700 days (interquartile range 362-1,173 days), aCRT reduced the risk of the clinical outcome, even in patients with mildly wide QRS or non-LBBB (log-rank P=0.0030 and P=0.0077, respectively) by Kaplan-Meier analysis. Use of the aCRT algorithm was an independent predictor of clinical outcomes in the multivariate analysis (hazard ratio (HR) 0.28, 95% confidence interval (CI): 0.096-0.78, P=0.015), the same as in patients with mildly wide QRS (HR 0.12, 95% CI: 0.006-0.69, P=0.015).

CONCLUSIONS

The new aCRT algorithm was useful and significantly reduced the risk of the clinical outcome, even in patients with mildly wide QRS.

Для цитирования: Ueda Nobuhiko, Noda Takashi, Ishibashi Kohei, Nakajima Kenzaburo, Kataoka Naoya, Kamakura Tsukasa, Wada Mitsuru, Yamagata Kenichiro, Inoue Yuko, Miyamoto Koji, Nagase Satoshi, Aiba Takeshi, Kanzaki Hideaki, Izumi Chisato, Noguchi Teruo, Yasuda Satoshi, Kusano Kengo. Efficacy of a Device-Based Continuous Optimization Algorithm for Patients With Cardiac Resynchronization Therapy.. Circulation journal : official journal of the Japanese Circulation Society. 2019. DOI: 10.1253/circj.cj-19-0691.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.