MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrthm.2019.05.009

Медицинская библиотека · Heart rhythm · 2019

On-treatment comparison between corrective His bundle pacing and biventricular pacing for cardiac resynchronization: A secondary analysis of the His-SYNC Pilot Trial.

Upadhyay Gaurav A, Vijayaraman Pugazhendhi, Nayak Hemal M, Verma Nishant, Dandamudi Gopi, Sharma Parikshit S, Saleem Moeen, Mandrola John, Genovese Davide, Oren Jess W, Subzposh Faiz A, Aziz Zaid, Beaser Andrew, Shatz Dalise, Besser Stephanie, Lang Roberto M, Trohman Richard G, Knight Bradley P, Tung Roderick, His-SYNC Investigators

СтатьяМногоцентровое исследованиеРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

The His-SYNC pilot trial was the first randomized comparison between His bundle pacing in lieu of a left ventricular lead for cardiac resynchronization therapy (His-CRT) and biventricular pacing (BiV-CRT), but was limited by high rates of crossover.

OBJECTIVE

To evaluate the results of the His-SYNC pilot trial utilizing treatment-received (TR) and per-protocol (PP) analyses.

METHODS

The His-SYNC pilot was a multicenter, prospective, single-blinded, randomized, controlled trial comparing His-CRT vs BiV-CRT in patients meeting standard indications for CRT (eg, NYHA II-IV patients with QRS >120 ms). Crossovers were required based on prespecified criteria. The primary endpoints analyzed included improvement in QRS duration, left ventricular ejection fraction (LVEF), and freedom from cardiovascular (CV) hospitalization and mortality.

RESULTS

Among 41 patients enrolled (aged 64 ± 13 years, 38% female, LVEF 28%, QRS 168 ± 18 ms), 21 were randomized to His-CRT and 20 to BiV-CRT. Crossover occurred in 48% of His-CRT and 26% of BiV-CRT. The most common reason for crossover from His-CRT was inability to correct QRS owing to nonspecific intraventricular conduction delay (n = 5). Patients treated with His-CRT demonstrated greater QRS narrowing compared to BiV (125 ± 22 ms vs 164 ± 25 ms [TR], P < .001;124 ± 19 ms vs 162 ± 24 ms [PP], P < .001). A trend toward higher echocardiographic response was also observed (80 vs 57% [TR], P = .14; 91% vs 54% [PP], P = .078). No significant differences in CV hospitalization or mortality were observed.

CONCLUSIONS

Patients receiving His-CRT on-treatment demonstrated superior electrical resynchronization and a trend toward higher echocardiographic response than BiV-CRT. Larger prospective studies may be justifiable with refinements in patient selection and implantation techniques to minimize crossovers.

Для цитирования: Upadhyay Gaurav A, Vijayaraman Pugazhendhi, Nayak Hemal M, Verma Nishant, Dandamudi Gopi, Sharma Parikshit S, Saleem Moeen, Mandrola John, Genovese Davide, Oren Jess W, Subzposh Faiz A, Aziz Zaid, Beaser Andrew, Shatz Dalise, Besser Stephanie, Lang Roberto M, Trohman Richard G, Knight Bradley P, Tung Roderick, His-SYNC Investigators. On-treatment comparison between corrective His bundle pacing and biventricular pacing for cardiac resynchronization: A secondary analysis of the His-SYNC Pilot Trial.. Heart rhythm. 2019. DOI: 10.1016/j.hrthm.2019.05.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.