MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5603/kp.a2016.0057

Медицинская библиотека · Kardiologia polska · 2016

Prediction of troponin elevation by means of intracoronary electrocardiogram during percutaneous coronary intervention of coronary bifurcation lesions (from COronary SIde Branch Residual IschemiA and COllateralization Assessment Study; COSIBRIA & Co Study.

Vassilev Dobrin, Dosev Liubomir, Rigatelli Gianluca, Karamfiloff Kiril, Popov Hristo, Nikolov Lachezar, Ivanov Kristian, Entcheva-Dimitrov Plamena, Golebiewski Slawomir, Gil Robert J, Kassab Ghassan S, Bil Jacek

Клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The influence of periprocedural ischaemia on coronary artery bifurcation stenting (percutaneous coronary intervention [PCI]) remains uncertain.

AIM: To determine the differences in rates of end procedural ischaemia after bifurcation lesion PCI detected with intracoronary electrocardiography (icECG).

METHODS

Unipolar icECGs were recorded before, during, and after stent placement and at the end of procedure in side branch (SB) and main branch (MB). Coronary wire was placed in all distal vessels with diameter > 1.5 mm to "map" the distal zones of ischaemia. The patient population consisted of patients with stable/unstable angina with troponin I evaluated before and after PCI.

RESULTS

We studied 147 patients (68% males) with mean age of 64 ± 9 years. One hundred and forty-two patients had icECG recordings at the end of PCI from all locations of the treated region; 36% of patients had MB ST segment elevation (STE) and 31% had icECG STE in the SB region (p = 0.378). The icECG had sensitivity of 82% and specificity of 81% to detect troponin I elevation, with positive predictive value of 81% and negative predictive value of 83%. The independent predictors of troponin increase (> 5 × N) were: sex (for female gender, OR = 0.130, CI 0.017-0.995, p = 0.049), previous myocardial infarction (OR = 33.23, CI 2.802-394.1, p = 0.005), and icECG STE in MB or SB or occlusion of secondary SB (OR = 7.877, CI 2.474-25.07, p < 0.001) and for any troponin elevation were double product - SBPxHR (OR = 0.999, CI 0.999-1.00, p = 0.022) and icECG STE in MB or SB or occlusion of secondary SB (OR = 9.762, CI 3.273-29.12, p < 0.001).

CONCLUSIONS

Intracoronary electrocardiography is a highly sensitive and specific method for determination of ischaemic regions and prediction of elevated troponin I.

Для цитирования: Vassilev Dobrin, Dosev Liubomir, Rigatelli Gianluca, Karamfiloff Kiril, Popov Hristo, Nikolov Lachezar, Ivanov Kristian, Entcheva-Dimitrov Plamena, Golebiewski Slawomir, Gil Robert J, Kassab Ghassan S, Bil Jacek. Prediction of troponin elevation by means of intracoronary electrocardiogram during percutaneous coronary intervention of coronary bifurcation lesions (from COronary SIde Branch Residual IschemiA and COllateralization Assessment Study; COSIBRIA & Co Study.. Kardiologia polska. 2016. DOI: 10.5603/kp.a2016.0057.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.