m+Medelevator.RU
← Поиск публикаций
Global heart · 2024

Pilot Study of Intelligent Office Blood Pressure Measurement Model in Shanghai, China, 2022.

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Wu Guoli, Yan Qinghua, Martínez-García Fernando, Neupane Dinesh, Wang Yuheng, Wu Fei, Wu Cui, Smith Barbara Lee, Shi Yan, Cheng Minna

Аннотация

INTRODUCTION: An intelligent office blood pressure measurement (IOBPM) model for community-based hypertension management was piloted in Shanghai, China, to overcome the conventional blood pressure management (CBPM) model's deficiencies.

METHODS: We selected adults aged 35-89 years who were being treated and managed for hypertension in two community health centers for the IOBPM and CBPM models. The IOBPM model consisted of two or three consecutive blood pressure (BP) measurements using a pre-programmed and validated automatic device. The BP data for the CBPM model were obtained from the routine follow-up records of hypertensive patients and derived from the Shanghai Non-communicable Diseases Management Information System. Subjects in the IOBPM model were selected by a simple random sampling method, and propensity score matching was used to select a comparable control population from the CBPM model based on important covariables. The BP levels, end-digit preferences, frequency distribution, and BP control were compared between the two models.

RESULTS: We selected 2,909 patients for the IOBPM model and 5,744 for the CBPM model. The systolic BP in the CBPM model was 12.3 mmHg lower than in the IOBPM model. In the CBPM model, there were statistically significant end-digit preferences (P < 0.001), with zero being the most reported end-digit (23.3% for systolic BP and 27.7% for diastolic BP). There was no significant end-digit preference in the IOBPM model. Certain BP values below 140/90 mmHg in the CBPM model were more frequent, while the IOBPM model showed a normal distribution. The BP control in the CBPM model was significantly higher than the IOBPM model (P < 0.001).

CONCLUSION: The IOBPM model appears to overcome the deficiencies of the CBPM model, leading to more accurate and reliable BP measurements.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты