Automatic extraction of the mitral valve chordae geometry for biomechanical simulation.

Panicheva Daryna, Villard Pierre-Frédéric, Hammer Peter E, Perrin Douglas, Berger Marie-Odile

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Mitral valve computational models are widely studied in the literature. They can be used for preoperative planning or anatomical understanding. Manual extraction of the valve geometry on medical images is tedious and requires special training, while automatic segmentation is still an open problem.

METHODS

We propose here a fully automatic pipeline to extract the valve chordae architecture compatible with a computational model. First, an initial segmentation is obtained by sub-mesh topology analysis and RANSAC-like model-fitting procedure. Then, the chordal structure is optimized with respect to objective functions based on mechanical, anatomical, and image-based considerations.

RESULTS

The approach has been validated on 5 micro-CT scans with a graph-based metric and has shown an [Formula: see text] accuracy rate. The method has also been tested within a structural simulation of the mitral valve closed state.

CONCLUSION

Our results show that the chordae architecture resulting from our algorithm can give results similar to experienced users while providing an equivalent biomechanical simulation.

Для цитирования: Panicheva Daryna, Villard Pierre-Frédéric, Hammer Peter E, Perrin Douglas, Berger Marie-Odile. Automatic extraction of the mitral valve chordae geometry for biomechanical simulation.. International journal of computer assisted radiology and surgery. 2021. DOI: 10.1007/s11548-021-02368-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.