DOI 10.1097/mat.0000000000001248

Медицинская библиотека · ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2021

Inflow Cannula Position Influences Improvement in Mitral Regurgitation After Ventricular Assist Device Implantation.

Pasrija Chetan, Sawan Mariem A, Sorensen Erik, Gammie James S, Madathil Ronson, Tran Douglas, Wang Libin, Ton Van-Khue, Feller Erika, Griffith Bartley P, Kon Zachary N, Kaczorowski David J

СтатьяПеревод пока не подготовлен

Аннотация

Significant residual mitral regurgitation (MR) after left ventricular assist device (LVAD) implantation has been associated with increased morbidity and mortality. The effect of cannula position on improvement of preexisting MR has yet to be evaluated. Consecutive patients who underwent centrifugal LVAD implantation with >mild preoperative MR and without concomitant mitral repair were reviewed. Left ventricular assist device position was determined by the angle between actual and ideal inflow cannula on computed tomography. The magnitudes of angles (anterior and lateral angle) were added to form an LVAD position assessment (LVADpa). Mitral regurgitation was numerically classified, and improvement in MR was determined by difference in MR preoperatively to MR >1 month postoperatively with a median of 162 (interquartile range: 78-218) days. The primary analysis examined the relationship between LVADpa and postoperative MR. Forty-one patients were identified with >mild preoperative functional MR. Mean age was 51 ± 13 years with an ejection fraction of 16 ± 4%. Overall, MR improved from moderate-severe preoperatively to mild postoperatively (p < 0.001). On multivariable analysis, higher LVADpa deviation was associated with greater postoperative MR (odds ratio [OR] = 2.29, p = 0.005) and higher 1-month pulsatility index was associated with lower postoperative MR (OR = 0.47, p = 0.011). Inflow cannula position during centrifugal LVAD implantation is an important determinant of postoperative MR.

Для цитирования: Pasrija Chetan, Sawan Mariem A, Sorensen Erik, Gammie James S, Madathil Ronson, Tran Douglas, Wang Libin, Ton Van-Khue, Feller Erika, Griffith Bartley P, Kon Zachary N, Kaczorowski David J. Inflow Cannula Position Influences Improvement in Mitral Regurgitation After Ventricular Assist Device Implantation.. ASAIO journal (American Society for Artificial Internal Organs : 1992). 2021. DOI: 10.1097/mat.0000000000001248.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.