MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.rxeng.2025.501735

Медицинская библиотека · Radiologia · 2025

Imaging localization strategies in primary hyperparathyroidism.

Adarve Castro A, Soria Utrilla V, Castro-García J M, Morales García D, Ruiz-Gómez M J, Sendra Portero F, Domínguez Pinos D

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Parathyroid glands exhibit a notable anatomical variability, complicating preoperative localization. Minimally invasive parathyroidectomy ideally requires two concordant imaging tests. This study aims to evaluate the degree of concordance of the different tests available with surgical findings and to create an algorithm to discern the order in which these tests should be performed.

METHODS

This prospective study included 93 patients with primary hyperparathyroidism (PHP) undergoing 99mTc-sestamibi SPECT/CT and cervical ultrasound. Discordant cases underwent secondary imaging (contrast-enhanced ultrasound [CEUS], CT, MRI, or 18F-choline PET/CT) based on endocrinologist criteria. Sensitivity, positive predictive value (PPV), accuracy, and Cohen's Kappa index (k) relative to surgical outcomes were calculated for each modality.

RESULTS

Of the 93 patients studied, 46 (49.5 %) were included in Group A (concordant location between 99Tc-sestaMIBI and ultrasound) and 47 (50.5 %) in Group B (discordant initial tests). Overall, 99mTc-sestamibi SPECT/CT showed κ = 0.55 (p < 0.001), while ultrasound demonstrated κ = 0.67 (p < 0.001). In Group B, imaging tests yielded the following κ values: CEUS = 0.64 (p < 0.001), 18F-choline PET/CT = 0.62 (p = 0.013), CT = 0.54 (p = 0.002), ultrasound = 0.43 (p < 0.001), 99mTc-sestamibi SPECT/CT = 0.34 (p = 0.013) and MRI = 0.14 (p = 0.145).

CONCLUSION

In patients with PHP with surgical criteria in whom initial scintigraphy and ultrasound were concordant, both tests showed moderate concordance with surgery. In discordant cases, CEUS showed the greatest concordance with surgery, followed by 18F-choline PET/CT. Thus, we propose an algorithm in which localization tests should be performed in a certain order based on the performance of each test in each possible scenario.

Для цитирования: Adarve Castro A, Soria Utrilla V, Castro-García J M, Morales García D, Ruiz-Gómez M J, Sendra Portero F, Domínguez Pinos D. Imaging localization strategies in primary hyperparathyroidism.. Radiologia. 2025. DOI: 10.1016/j.rxeng.2025.501735.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.