Efficacy and safety of high-intensity, high-frequency, non-focused ultrasound parallel beams for facial skin laxity.

Gold Michael H, Biron Julie

Клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Ultrasound energy has been used for dermal rejuvenation to treat fine lines, wrinkles and to lift lax skin. High intensity ultrasound waves induce thermal injury in the dermis, stimulating neocollagenesis and neoelastinogenesis.

OBJECTIVE

To assess the efficacy, utility, and safety of a novel ultrasound device that uses high-intensity, high-frequency, non-focused ultrasound parallel beams to lift lax facial skin in the eyebrow, submental, and neck areas.

MATERIALS AND

METHODS

Fifteen subjects aged 40-69 years were enrolled in a prospective clinical trial. Two treatment sessions were performed with the high-intensity non-focused ultrasound parallel beam device followed by 3- and 6-month follow-up visits. Treatment results were assessed by study investigators, evaluating baseline and posttreatment photographs by applying physician global aesthetic improvement scale. Pain was evaluated immediately after each treatment using 0-10 visual analog scale. Any adverse event that occurred during the study period was documented and examined.

RESULTS

Fifteen subjects with a mean age of 55 ± 2 years completed the study. Photographs that were taken at baseline and follow-up visits were compared and examined. An improvement pattern was detected in all treated areas in both follow-up visits and persisted stably throughout the study. The mean pain score was 5.6 according to the visual analog scale.

CONCLUSION

The novel ultrasound device that uses high-intensity, high-frequency, non-focused ultrasound parallel beam was shown to improve safely and efficiently facial lax skin resulting in eyebrow, submental, and neck skin lift while experiencing tolerable pain.

Для цитирования: Gold Michael H, Biron Julie. Efficacy and safety of high-intensity, high-frequency, non-focused ultrasound parallel beams for facial skin laxity.. Journal of cosmetic dermatology. 2023. DOI: 10.1111/jocd.16098.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.