DOI 10.1097/gox.0000000000007175

Медицинская библиотека · Plastic and reconstructive surgery. Global open · 2025

Ultrasonographic Measurement After Multilayer Stimulation for Body Fat Reduction and Muscle Strengthening: A Pilot Study.

Bae Kyung-Tae, Jung Hye-Won, Lee Dong-Shin, Wan Jovian, Yi Kyu-Ho

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Demand for noninvasive body contouring is rising as patients seek alternatives to liposuction. We evaluated a device combining electrical muscle stimulation, radiofrequency, and vacuum technology for abdominal fat reduction and muscle enhancement.

METHODS

In a prospective study, 20 adults (15 women, 5 men; 28-50 y; body mass index [BMI] 22-28 kg/m²) received 16 sessions over 8 weeks (two 30-min sessions/wk) targeting the abdomen. Outcomes at baseline and 1 month posttreatment included ultrasonographic abdominal fat and muscle thickness, waist circumference, BMI, standardized photography, and patient-reported satisfaction. Safety and downtime were documented.

RESULTS

At 1 month, mean abdominal fat thickness decreased by 0.61 cm (95% confidence interval [CI], 0.48-0.74; P < 0.001), and muscle thickness increased by 0.24 cm (95% CI, 0.17-0.31; P < 0.001). Waist circumference reduced by 2.13 cm (95% CI, 1.81-2.45; P < 0.001), and BMI changed by -0.53 (95% CI, -0.59 to -0.54; P < 0.001). Standardized images and patient ratings indicated improved contour and skin elasticity. The treatments were well tolerated, with high satisfaction and minimal downtime.

CONCLUSIONS

Combined electrical muscle stimulation, radiofrequency, and vacuum therapy produced significant reductions in abdominal fat and waist size, increased muscle thickness, and improved perceived contour with favorable tolerability. These findings support this multimodal, noninvasive approach as a promising option for abdominal shaping.

Для цитирования: Bae Kyung-Tae, Jung Hye-Won, Lee Dong-Shin, Wan Jovian, Yi Kyu-Ho. Ultrasonographic Measurement After Multilayer Stimulation for Body Fat Reduction and Muscle Strengthening: A Pilot Study.. Plastic and reconstructive surgery. Global open. 2025. DOI: 10.1097/gox.0000000000007175.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.