MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jum.16109

Медицинская библиотека · Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2022

Fetal Cardiac Inflow Characteristics in Response to Fetal Anemia: Based on Fetal Hemoglobin Bart's Disease at Mid-Pregnancy.

Sirivat Kanthong, Luewan Suchaya, Srisupundit Kasemsri, Jatavan Phudit, Tongsong Theera

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To identify the inflow (filling time fraction [FTF] and E/A ratio) characteristics of fetuses with anemia, and to evaluate the performance of the inflow markers in predicting the affected fetuses.

METHODS

Fetuses at risk of hemoglobin (Hb) Bart's disease at 17-22 weeks were prospectively recruited to undergo echocardiography before diagnostic cordocentesis. Cardiac Doppler images were digitally stored for off-line blinded measurements of FTF and E/A ratio.

RESULTS

A total of 428 fetuses at risk of Hb Bart's disease were analyzed, including 88 affected fetuses (20.6%). The mean gestational age at the time of diagnosis was 19.43 ± 1.5 weeks. The FTFs in both sides were significantly lower in the affected fetuses, whereas the E/A ratios of both sides were significantly higher in the affected group. According to the receiver operating characteristic curves, the performance of the FTF of the right side in predicting affected fetuses was slightly better than that of the left side (area under curve: 0.707 versus 0.680, P < .001). Likewise, the performance of the E/A ratio of the tricuspid valve was slightly better than that of the mitral valve. Also, FTF was superior to E/A ratio in predicting the affected fetuses.

CONCLUSIONS

New insights leading to a better understanding of the fetal cardiac response to anemia are: 1) the FTFs in both sides were significantly decreased, suggesting some degree of diastolic ventricular dysfunction; 2) the E/A ratios of both sides were significantly increased, indicating volume load; and 3) The inflow parameters may be useful as a new predictor of fetal anemia, especially among pregnancies at risk.

Для цитирования: Sirivat Kanthong, Luewan Suchaya, Srisupundit Kasemsri, Jatavan Phudit, Tongsong Theera. Fetal Cardiac Inflow Characteristics in Response to Fetal Anemia: Based on Fetal Hemoglobin Bart's Disease at Mid-Pregnancy.. Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine. 2022. DOI: 10.1002/jum.16109.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.