World journal of gastrointestinal endoscopy · 2018
New 14-mm diameter Niti-S biliary uncovered metal stent for unresectable distal biliary malignant obstruction.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Kikuyama Masataka, Shirane Naofumi, Kawaguchi Shinya, Terada Shuzou, Mukai Tsuyoshi, Sugimoto Ken
Аннотация
AIM: To investigate whether an uncovered self-expandable metal stent (UCSEMS) with a large diameter could prevent recurrent biliary obstruction (RBO).
METHODS: Thirty-eight patients with malignant biliary obstruction underwent treatment with an UCSEMS with a 14-mm diameter (Niti-S 14). Retrospectively, we evaluated technical and functional success rate, RBO rate, time to RBO, survival time, and adverse events in these patients.
RESULTS: Stent placement success and functional success were achieved in all patients. Two patients (5.3%) had RBO due to tumor ingrowth or overgrowth. The median time to RBO was 190 (range, 164-215) d. The median survival time was 120 (range, 18-502) d. The 6-mo non-RBO rate was 91%. Other adverse events other than RBO occurred as follows: Acute cholecystitis, post-ERCP pancreatitis, hemobilia, and fever without exacerbation of liver injury, and liver abscess in 4 (10.3%), 3 (7.9%), 2 (5.3%), 1 (2.6%), and 1 (2.6%), respectively. Migration of the stents was not observed.
CONCLUSION: Niti-S 14 is considered to be a preferable metal stent because of a low rate of RBO with no migration.
METHODS: Thirty-eight patients with malignant biliary obstruction underwent treatment with an UCSEMS with a 14-mm diameter (Niti-S 14). Retrospectively, we evaluated technical and functional success rate, RBO rate, time to RBO, survival time, and adverse events in these patients.
RESULTS: Stent placement success and functional success were achieved in all patients. Two patients (5.3%) had RBO due to tumor ingrowth or overgrowth. The median time to RBO was 190 (range, 164-215) d. The median survival time was 120 (range, 18-502) d. The 6-mo non-RBO rate was 91%. Other adverse events other than RBO occurred as follows: Acute cholecystitis, post-ERCP pancreatitis, hemobilia, and fever without exacerbation of liver injury, and liver abscess in 4 (10.3%), 3 (7.9%), 2 (5.3%), 1 (2.6%), and 1 (2.6%), respectively. Migration of the stents was not observed.
CONCLUSION: Niti-S 14 is considered to be a preferable metal stent because of a low rate of RBO with no migration.