DOI 10.1016/j.radi.2025.103275
Comparison of image quality, radiation dose and repeat rates for anteroposterior (AP) pelvic radiography imaging techniques (STOPPAGE study).
Аннотация
INTRODUCTION
Pelvic radiography is common technique for investigating hip pain, pre-operative planning and in post-surgical surveillance. Variations in anteroposterior (AP) radiographic technique have been described in the literature and are in routine practice. The aim of this study was to compare a single standardised technique (Intervention-Site 1) against individual radiographer determined techniques (Control-Site 2).
METHODS
The study was prospective in design and recruited adult ambulant patients referred for pelvic radiography. Site 1 'Intervention' used a single standardised AP technique and Site 2 'Control' allowed radiographers to determine their own optimum technique. Comparisons between the study sites included radiation dose, image quality and repeat rates. It was hypothesised that Site 1 would have lower radiation doses and fewer repeats. Demographics including sex, age and BMI were collected to ensure comparability between sites.
RESULTS
292 patients were recruited 161 (55 %) from Site 1 and 131 (45 %) Site 2. There were no statistically significant differences in terms of male to female ratio, age and BMI (p > 0.05). Median (IQR) DAP values were insignificantly lower at Site 2 11.4 (7.9-14.3) dGy.cm2 when compared to Site 1 12.9 (8.2-18.6) dGy.cm2 (p = 0.07). Repeat rates were marginally higher at Site 1 (24 %) when compared to Site 2 (19 %), but not statistically significant (p = 0.291). The missing of anatomical structures was statistically less frequent at Site 1 (12 %) when compared to Site 2 (24 %) (p = 0.009).
CONCLUSION
Initial evaluation of study data suggests that radiation doses and repeat rates were comparable. Opting for a standardised technique may yield more technically 'perfect' radiographs.
IMPLICATIONS FOR PRACTICE: Outside of radiation dose and repeat rates a standardised pelvic X-ray technique may yield improvements in technical completeness and image quality.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.