MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1365-2265.1995.tb00545.x

Медицинская библиотека · Clinical endocrinology · 1995

Cardiovascular and metabolic responses to adrenaline infusion in patients with short-term hypothyroidism.

Johnson A B, Webber J, Mansell P, Gallen I, Allison S P, Macdonald I

Клиническое исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

The relation between the clinical manifestations of thyroid disease (both hypo and hyper-thyroidism) and tissue sensitivity to catecholamines remains uncertain. It has been suggested that tissue adrenergic responsiveness is decreased in hypothyroidism, but the reports have been conflicting and have invariably focused on a single physiological response. Therefore the aim of the present study was to determine in patients with moderate, short-term, symptomatic hypothyroidism the responses of heart rate, systolic and diastolic blood pressure, forearm blood flow and metabolic rate to adrenaline infused at a rate known to achieve plasma concentrations in the middle of the physiological range.

PATIENTS: Ten subjects (5M, age 43 +/- 3 years, mean +/- SEM) were studied. All were on thyroxine replacement for hypothyroidism following either thyroidectomy or radioactive iodine and had been biochemically euthyroid for at least 6 months.

DESIGN

Studies were performed in random order. One study was undertaken on full replacement therapy and the other after 50 micrograms thyroxine daily for 2 weeks. After basal, supine measurements adrenaline was infused at 25 ng/kg/min for 30 minutes.

MEASUREMENTS: Heart rate, blood pressure, blood glucose, metabolic rate and forearm blood flow were measured at rest and at 10-minute intervals throughout the adrenaline infusion.

RESULTS

Free T4 (10.6 +/- 1.3 vs 17.6 +/- 2.0 pmol/l, P < 0.001) and free T3 (3.6 +/- 0.2 vs 4.6 +/- 0.3 pmol/l, P < 0.01) concentrations were significantly lower on 50 micrograms thyroxine than full replacement therapy. Fasting blood glucose concentrations (4.7 +/- 0.2 vs 4.7 +/- 0.1 mmol/l) were similar. The resting adrenaline concentrations were comparable, 0.29 +/- 0.18 and 0.24 +/- 0.14 nmol/l on 50 micrograms thyroxine and full replacement therapy respectively, and increased to a similar level (2.36 +/- 0.39 and 2.36 +/- 0.35 nmol/l) throughout the adrenaline infusion. The resting heart rate and metabolic rate were significantly lower on 50 micrograms thyroxine than full replacement therapy (68 +/- 2 vs 72 +/- 3 beats/min, P < 0.01; and 4.48 +/- 0.35 vs 4.88 +/- 0.39 kJ/min, P < 0.01) respectively, but the increase in heart rate (7 +/- 2 vs 8 +/- 2 beats/min) and metabolic rate (0.43 +/- 0.09 vs 0.43 +/- 0.06 kJ/min) did not differ on the two study days. Resting systolic blood pressure, diastolic blood pressure and forearm blood flow were comparable on 50 micrograms thyroxine and full replacement therapy as were the changes in systolic blood pressure (1 +/- 1 vs 1 +/- 1 mmHg), diastolic blood pressure (-7 +/- 2 vs -7 +/- 1 mmHg), forearm blood flow (1.4 +/- 0.1 vs 1.7 +/- 0.2 ml/min/100ml forearm) and blood glucose concentration (0.7 +/- 0.1 vs 0.7 +/- 0.1 mmol/l).

CONCLUSIONS

Patients with short-term hypothyroidism appear to have a normal response to adrenaline infusion despite reduced baseline heart rate and metabolic rate. Thus, under physiological and mild pathophysiological conditions there appears to be no evidence of any synergy between thyroid status and sensitivity to catecholamines.

Для цитирования: Johnson A B, Webber J, Mansell P, Gallen I, Allison S P, Macdonald I. Cardiovascular and metabolic responses to adrenaline infusion in patients with short-term hypothyroidism.. Clinical endocrinology. 1995. DOI: 10.1111/j.1365-2265.1995.tb00545.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.