MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jjcc.2024.01.001

Медицинская библиотека · Journal of cardiology · 2024

Minimum-incision transsubclavian transcatheter aortic valve replacement with balloon-expandable valve for dialysis patients.

Domoto Satoru, Yamaguchi Junichi, Tsuchiya Ken, Inagaki Yusuke, Nakamae Kosuke, Hirota Masataka, Arashi Hiroyuki, Hanafusa Norio, Hoshino Junichi, Niinami Hiroshi

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Dialysis patients undergoing transcatheter aortic valve replacement (TAVR) face increased risk and have poorer outcomes than non-dialysis patients. Moreover, TAVR in dialysis patients using an alternative approach is considered extremely risky and little is known about the outcomes. We routinely perform minimum-incision transsubclavian TAVR (MITS-TAVR), which is contraindicated for transfemoral (TF) TAVR. This study aimed to evaluate the outcomes of MITS-TAVR compared with those of TF-TAVR in dialysis patients.

METHODS

This single-center, observational study included 79 consecutive dialysis patients who underwent MITS-TAVR (MITS group, n = 22) or TF-TAVR (TF group, n = 57) under regional anesthesia.

RESULTS

The rates of peripheral artery disease (MITS vs. TF, 72.7 % vs. 26.3 %; p < 0.01), shaggy aortas (MITS vs. TF, 63.6 % vs. 5.26 %; p < 0.01), and tortuous aortas (MITS vs. TF, 13.6 % vs. 1.75 %; p = 0.031) were significantly higher in the MITS group. The 30-day mortality was 2.53 % and comparable between the two groups (MITS vs. TF, 4.54 % vs. 1.75 %; p = 0.479). In the MITS group, 14 patients had ipsilateral dialysis fistulas, and three patients had patent in situ ipsilateral internal thoracic artery grafts; however, no vascular complications were observed. Kaplan-Meier survival curves for the two groups showed no significant difference in the survival rate (at 2 years; MITS vs. TF, 77.3 % vs. 68.8 %; p = 0.840) and freedom from cardiovascular mortality (at 2 years; MITS vs. TF, 90.9 % vs. 96.5 %; p = 0.898). The multivariable Cox proportional hazard model also indicated that survival in the MITS group was not significantly different from that in the TF group (hazard ratio 1.48; 95 % confidence interval, 0.77-2.85, p = 0.244). The patency rate of ipsilateral dialysis fistula was 100 % during follow-up.

CONCLUSION

The outcome of MITS-TAVR was comparable to that of TF-TAVR in dialysis patients, despite the higher risk of patient characteristics.

Для цитирования: Domoto Satoru, Yamaguchi Junichi, Tsuchiya Ken, Inagaki Yusuke, Nakamae Kosuke, Hirota Masataka, Arashi Hiroyuki, Hanafusa Norio, Hoshino Junichi, Niinami Hiroshi. Minimum-incision transsubclavian transcatheter aortic valve replacement with balloon-expandable valve for dialysis patients.. Journal of cardiology. 2024. DOI: 10.1016/j.jjcc.2024.01.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.