Third-Generation Transcatheter Aortic Heart Valve with Reverse Parachute Sealing Cuff in Patients with Aortic Valve Disease.

Malhotra Ganeev, Cole Chris M W, Cox Stephen V, Ross Jordan D W, Dooris Mark, Moore Peter T, Chong Adrian A, Dahiya Arun, Korver Kellee, Hayman Sam M, Camuglia Anthony C

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The Navitor (Abbott Inc, IL, USA) transcatheter heart valve is a novel third-generation self-expanding bioprosthesis with specific features to mitigate paravalvular regurgitation (PVR). Owing to its novelty, there is a paucity of data on its application in clinical practice.

METHODS

Consecutive cohort analysis of the use of the Navitor system in an as-treated clinical setting at a quaternary heart hospital.

RESULTS

Sixty consecutive non-clinical trial patients treated with Navitor were identified. All patients underwent a successful procedure. The mean age was 79.3 years (±SD 7.82), 56.67% (n=34) were female, and the mean STS score was 4.87 (±SD 5.70). At 30 days post-procedure, all patients were alive with no readmissions for heart failure. One patient had a major vascular complication (1.7%). Four patients (7.14% of patients without a pre-existing pacemaker) received a new permanent pacemaker. Two patients (3.4%) had a non-disabling stroke. PVR at 30 days was trivial or none in 75% of patients, and no patient had worse than mild PVR.

CONCLUSIONS

The Navitor system in this as-treated cohort was associated with favourable clinical, haemodynamic, and safety outcomes.

Для цитирования: Malhotra Ganeev, Cole Chris M W, Cox Stephen V, Ross Jordan D W, Dooris Mark, Moore Peter T, Chong Adrian A, Dahiya Arun, Korver Kellee, Hayman Sam M, Camuglia Anthony C. Third-Generation Transcatheter Aortic Heart Valve with Reverse Parachute Sealing Cuff in Patients with Aortic Valve Disease.. Heart, lung & circulation. 2024. DOI: 10.1016/j.hlc.2023.11.019.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.